Drug transport from blood to extravascular tissue can locally be achieved by increasing the vascular permeability through ultrasound-activated microbubbles. However, the mechanism remains unknown, including whether short and long cycles of ultrasound induce the same onset rate, spatial distribution, and amount of vascular permeability increase. Accurate models are necessary for insights into the mechanism so a microvessel-on-a-chip is developed with a membrane-free extravascular space. Using these microvessels-on-a-chip, distinct differences between 2 MHz ultrasound treatments are shown with 10 or 1000 cycles. The onset rate is slower for 10 than 1000 cycles, while both cycle lengths increase the permeability in spot-wise patterns without affecting microvessel viability. Significantly less vascular permeability increase and sonoporation are induced for 10 versus 1000 cycles at 750 kPa (i.e., the highest studied peak negative acoustic pressure (PNP)). The PNP threshold for vascular permeability increases is 750 versus 550 kPa for 10 versus 1000 cycles, while this is 750 versus 220 kPa for sonoporation. Vascular permeability increases do not correlate with alpha v beta 3-targeted microbubble behavior, while sonoporation correlates with alpha v beta 3-targeted microbubble clustering. In conclusion, the further mechanistic unraveling of vascular permeability increase by ultrasound-activated microbubbles in a developed microvessel-on-a-chip model aids the safe and efficient development of microbubble-mediated drug transport.
Keywords:
microbubbles
Microvessel-on-a-chip
sonoporation
ultrasound
vascular permeability
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Small cover
Small
IF:
12.1
Papers:
3.0W
Citations:
16.4W

Organization

E
erasmus mc cardiovascular institute
Scholars:
66
Papers: 46
Citations: 0
E
Erasmus University Rotterdam
Scholars:
4.6W
Papers: 4.0W
Citations: 2.4W
E
Erasmus MC
Scholars:
2.9W
Papers: 2.5W
Citations: 3.4W
researcher View more organizations