arrow
Return

Color Intensity Method for Hydrogel Oxygen Sensor Array

delete2010-12-01
delete19
PRE
AI
J
Jong‐Won Park *
W
Wonhak Hong
C
Chang-Soo Kim
DOI:10.1109/JSEN.2010.2049837delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
The oxygen imaging technique to obtain a 2-D distribution is a convenient method because it does not require individual addressing of each sensing element in a sensor array. Until recently, color charge coupled devices (CCDs) have rarely been used for oxygen imaging in spite of usefulness for analyzing the spectral content of images. In this work, a color CCD camera was used for luminescence intensity imaging. Two methods of color intensity analysis are investigated and compared. The first method is to analyze the total Red-Green-Blue (RGB) color intensity of the original color image. The second method involves extracting the red color element to enhance the sensitivity of oxygen measurement. Both commercial RedEye oxygen sensor patches and lab-made photopatterned hydrogel (polyethylene glycol) sensor arrays were used to verify these methods. The linearity and sensitivity of oxygen detection based on the red intensity analysis was improved to those of spectrometric measurement and total color intensity analysis. This method also has potential applications in lifetime imaging, multi-analyte detection, and simultaneous structural and functional imaging of biological systems.
Keywords:
Charge coupled devices (CCD)
imaging
luminescence
poly(ethylene glycol) (PEG)
ruthenium
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

IEEE Sensors Journal cover
IEEE Sensors Journal
IF:
4.5
Papers:
2.2W
Citations:
7.3W

Organization

University of Missouri System cover
University of Missouri System
Scholars:
3.0W
Papers: 2.7W
Citations: 75
Cited Papers

Cited Papers

errShare
errSave
A microsystem for sensing and patterning oxidative microgradients during cell culture
err2006-01-01
err85
PREAI
errPark, J; Bansal, T; Pinelis, M; Maharbiz, MM
errShare
errSave
Read-out of multiple optical chemical sensors by means of digital color cameras
err2009-05-01
err34
PREAI
errStich, Matthias I. J.; Borisov, Sergey M.; Henne, Ulrich; Schaeferling, Michael
errShare
errSave
Reversible optical sensor strip for oxygen
err2008-09-09
err101
PREAI
errWang, Xu-dong; Chen, Xi; Xie, Zhao-xiong; Wang, Xiao-ru
errShare
errSave
Obstructive Lung Disease and Exposure to Burning Biomass Fuel in the Indoor Environment
err2012-09-01
err0
errOAAI
errGregory B. Diette; Roberto A. Accinelli; John R. Balmes; A. Sonia Buist; William Checkley; Paul Garbe; Nadia N. Hansel; Vikas Kapil; Stephen Gordon; David K. Lagat; Fuyuen Yip; Kevin Mortimer; Rogelio Perez-Padilla; Christa Roth; Julie M. Schwaninger; Antonello Punturieri; James P. Kiley
errShare
errSave
researcher View more