arrow
Return

Comparative analysis of photon-counting and energy-integrating detector CT to identify obstructive coronary artery disease

delete2025-11-14
delete0
delete
OA
AI
M
Melinda Boussoussou
M
Milán Vecsey-Nagy
Z
Zsófia Jokkel
B
Borbála Vattay
A
A. Kubovje
B
Barbara Sipos
M
Márton Kolossváry
A
Anikó Ilona Nagy
L
Lili Száraz
S
S. Beke
B
Bernard Schmidt
M
Máté G. Kiss
B
Béla Merkely
J
Josua A. Decker
T
Tilman Emrich
Á
Ákos Varga‐Szemes
M
Maurovich-Horvat, Pal
B
Bálint Szilveszter *
DOI:10.1007/s00330-025-12118-7delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
To evaluate the patient-, vessel- and segment-based diagnostic performance of photon-counting detector CT (PCD-CT) compared to energy-integrating detector CT (EID-CT) for detecting ≥ 50% or ≥ 70% stenosis using invasive coronary angiography (ICA) as a reference standard. Patients with stable chest pain and ≥ 50% stenosis detected on dual source PCD-CT who subsequently underwent ICA were prospectively enroled. Diagnostic accuracy was calculated for PCD-CT vs ICA and additionally for a patient cohort scanned with EID-CT with similar risk profiles and disease prevalence. A Monte Carlo simulation based on diagnostic accuracy parameters was performed to estimate the potential reduction in ICA referrals. A total of 143 patients (66 ± 9 years, 27.3% female) with 572 vessels and 2431 segments were evaluated with PCD-CT and ICA. Regarding EID-CT, 109 patients (65 ± 9 years, 31.0% female), 436 vessels and 1853 segments were assessed, with every patient undergoing ICA. PCD-CT demonstrated significantly higher accuracy than EID-CT in detecting ≥ 50% stenosis: 88.1% vs 77.9% (patient level), 91.6% vs 77.8% (vessel level), and 97.7% vs 92.4% (segment level) (p < 0.01 for all). For detecting ≥ 70% stenosis, PCD-CT also showed higher accuracy than EID-CT: 90.9% vs 70.6% (patient level), 94.6% vs 80.9% (vessel level), and 98.6% vs 94.1% (segment level) (p < 0.01 for all). We demonstrated a potential mean reduction of 14.8% in ICA referrals when utilising PCD-CT compared to EID-CT. PCD-CT provides improved per-patient, per-vessel and per-segment diagnostic performance in detecting obstructive CAD in symptomatic patients when compared to patients scanned on EID-CT. PCD-CT may lead to a significant decrease in ICA utilisation. Question Accurate coronary CT angiography guides treatment, but its diagnostic accuracy is limited by various factors. Findings Photon counting detector (PCD)-CT improved diagnostic performance in detecting ≥ 50% or ≥ 70% stenosis, potentially reducing unnecessary ICA referrals by 14.8%. Clinical relevance PCD-CT improves diagnostic accuracy over EID-CT and may reduce unnecessary ICA.
Keywords:
Photon-counting detector CT
Invasive coronary angiography
Coronary stenosis
Diagnostic accuracy
Dual source CT
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

European Radiology cover
European Radiology
IF:
4.7
Papers:
1.6K
Citations:
3.9W

Organization

F
friedrich-alexander-university erlangen
Scholars:
4
Papers: 2
Citations: 0
D
department of diagnostic and interventional radiology
Scholars:
423
Papers: 160
Citations: 1
M
medical imaging centre
Scholars:
33
Papers: 13
Citations: 0
G
Gottsegen National Cardiovascular Center
Scholars:
53
Papers: 23
Citations: 83
researcher View more organizations