arrow
Return

Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted MRI

delete2016-02-22
delete98
delete
OA
AI
E
Eric Aliotta
H
Holden H. Wu
D
Daniel B. Ennis *
DOI:10.1002/mrm.26166delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
PurposeTo evaluate convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted imaging (DWI). MethodsDiffusion-encoding gradient waveforms were designed for a range of b-values and spatial resolutions with and without motion compensation using the CODE framework. CODE, first moment (M-1) nulled CODE-M-1, and first and second moment (M-2) nulled CODE-M1M2 were used to acquire neuro, liver, and cardiac ADC maps in healthy subjects (n=10) that were compared respectively to monopolar (MONO), BIPOLAR (M-1=0), and motion-compensated (MOCO, M-1+M-2=0) diffusion encoding. ResultsCODE significantly improved the SNR of neuro ADC maps compared with MONO (19.52.5 versus 14.5 +/- 1.9). CODE-M-1 liver ADCs were significantly lower (1.3 +/- 0.1 versus 1.8 +/- 0.3 x 10(-3) mm(2)/s, ie, less motion corrupted) and more spatially uniform (6% versus 55% ROI difference) than MONO and had higher SNR than BIPOLAR (SNR=14.9 +/- 5.3 versus 8.0 +/- 3.1). CODE-M1M2 cardiac ADCs were significantly lower than MONO (1.9 +/- 0.6 versus 3.8 +/- 0.3 x10(-3) mm(2)/s) throughout the cardiac cycle and had higher SNR than MOCO at systole (9.1 +/- 3.9 versus 7.0 +/- 2.6) while reporting similar ADCs (1.5 +/- 0.2 versus 1.4 +/- 0.6 x 10(-3) mm(2)/s). ConclusionsCODE significantly improved SNR for ADC mapping in the brain, liver and heart, and significantly improved DWI bulk motion robustness in the liver and heart. Magn Reson Med 77:717-729, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine
Keywords:
CONCOMITANT MAGNETIC-FIELD
FOCAL LIVER-LESIONS
ADC MEASUREMENTS
REPRODUCIBILITY
ARTIFACTS
DESIGN
SPACE
HEART
PULSE
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

University of California System cover
University of California System
Scholars:
37.7W
Papers: 33.8W
Citations: 6.6K
Cited Papers

Cited Papers

Evidence for neutral neutrino current coupling to right-handed quarks
err1989-11-01
err0
errOAAI
errJ.V. Allaby; U. Amaldi; G. Barbiellini; M. Baubillier; F. Bergsma; A. Capone; W. Flegel; L. Lanceri; M. Metcalf; C. Nieuwenhuis; R. Pain; J. Panman; K. Winter; I. Abt; V. Blobel; A. Büngener; F.W. Büsser; P.D. Gall; T. Hebbeker; F. Niebergall; P. Stähelin; P. Gorbunov; E. Grigoriev; V. Khovansky; A. Rosanov; B. Borgia; M. Diemoz; C. Dionisi; U. Dore; F. Ferroni; E. Longo; P.F. Loverre; L. Luminari; P. Monacelli; S. Morganti; F. De Notaristefani; R. Santacesaria; C. Santoni
errShare
errSave
Quantification of fibrosis in infarcted swine hearts by ex vivo late gadolinium-enhancement and diffusion-weighted MRI methods
err2013-07-08
err92
PREAI
errPop, Mihaela; Ghugre, Nilesh R.; Ramanan, Venkat; Morikawa, Lily; Stanisz, Greg; Dick, Alexander J.; Wright, Graham A.
errShare
errSave
Higher-Order Motion-Compensation for In Vivo Cardiac Diffusion Tensor Imaging in Rats
err2015-09-01
err61
errOAAI
errWelsh, Christopher L.; DiBella, Edward V. R.; Hsu, Edward W.
errShare
errSave
Fetters of gold and paper
err2010-11-09
err0
PREAI
errB. Eichengreen; P. Temin
errShare
errSave
Evaluation of optimized inversion-recovery fat-suppression techniques for T2-weighted abdominal MR imaging
err2008-05-26
err92
PREAI
errLauenstein, Thomas C.; Sharma, Puneet; Hughes, Timothy; Heberlein, Keith; Tudorascu, Dana; Martin, Diego R.
errShare
errSave
researcher View more