arrow
Return

Current Pulse Based Reference Electrodes Without Liquid Junctions

delete2013-03-27
delete20
PRE
AI
X
Xu U. Zou
P
Philippe Bühlmann *
DOI:10.1021/ac400507jdelete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Reference electrodes with hydrophobic ion-doped polymeric membranes offer a promising alternative to reference electrodes with conventional salt bridges. This letter introduces the current pulse operation of liquid junction free reference electrodes. A brief current pulse is applied to a cation exchanger membrane, releasing a well-controlled amount of cations from the membrane into the sample and, thereby, determining the boundary potential of the sample/reference membrane interface. Measurements with ion-selective electrodes (ISEs) are performed relative to these reference electrodes immediately after the current pulse and exhibit the same Nernstian responses as typical for potentiometry, which is demonstrated with Cl- ISE measurements. The use of current pulse based reference electrodes avoids the sample sensitivity and clogging of conventional salt bridges and the often poorly controlled loss of bridge electrolyte into samples. Current mode measurements in serum over 2 days showed a much higher stability of the reference potential than conventional potentiometric measurements with the same ion-doped polymeric membranes.
Keywords:
ION-SELECTIVE ELECTRODES
BULK OPTODES
SALT BRIDGE
VOLTAMMETRY
MEMBRANES
HEPARIN

Journal

Analytical Chemistry cover
Analytical Chemistry
IF:
6.7
Papers:
4.7W
Citations:
15.9W

Organization

No organization information available
Cited Papers

Cited Papers

Pulsed Dielectric-Surface Flashover in an $ \hbox{SF}_{6}$ Environment
err2007-10-01
err0
PREAI
errJohn T. Krile; Russell Vela; Andreas A. Neuber; Hermann G. Krompholz
errShare
errSave
Assessing 2D and 3D Heatmaps for Comparative Analysis
err2020-04-23
err0
errOAAI
errMatthias Kraus; Katrin Angerbauer; Juri Buchmüller; Daniel Schweitzer; Daniel A. Keim; Michael Sedlmair; Johannes Fuchs
errShare
errSave
The new wave of ion-selective electrodes.
err2002-08-01
err233
errOAAI
errBakker, E; Pretsch, E
errShare
errSave
Both Interleukin-3 and Interleukin-6 Are Necessary for Better Ex Vivo Expansion of CD133+ Cells From Umbilical Cord Blood
err2010-03-01
err0
PREAI
errPedro Bordeaux-Rego; Angela Luzo; Fernando Ferreira Costa; Sara Teresinha Olalla Saad; Daniella Pereira Crosara-Alberto
errShare
errSave
Time Projection Chambers for Gamma-Ray Astronomy
err2022-07-07
err0
PREAI
errDenis Bernard; Stanley D. Hunter; Toru Tanimori
errShare
errSave
researcher View more