Abstract

En 中文
Here, we developed and evaluated a filter-paper urine collection method for chlamydia and gonorrhea testing. Dried urine strips (DUS) were developed to fit into the sample collection tube used for high throughput Hologic Aptima Combo 2 assay, minimizing processing post-sample collection. Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) bacterial stock dilutions were used to assess DUS performance and long-term stability at different temperature conditions. DUS diagnostic performance was evaluated against urine samples with Aptima Combo 2 Assay and an in-house RT-PCR method for CT and NG detection utilizing residual diagnostic urine specimens (n = 60 CT and NG negative, n = 50 CT-positive and n = 55 NG-positive, including 5 CT/NG dual-positive). Replacing the overnight strip drying step with use of additional desiccants was evaluated in order to reduce barriers to self-sample collection. We observed a high degree of diagnostic accuracy (>91% sensitivity and >98% specificity), compared to traditional urine samples across all evaluated DUS preparation and storage methods. DUS samples demonstrated high stability for prolonged periods at tested temperature storage conditions with some loss in sensitivity at lower bacterial loads. While drying of the sample was crucial to preserve sample integrity and improve recovery post-elution, placing the DUS directly into the sample storage bag with additional desiccants did not negatively impact diagnostic performance. DUS specimens were shown suitable for downstream CT genotyping and NG sequence typing. The developed DUS represents an accurate and stable sample collection method for CT and NG diagnostic testing and downstream pathogen characterization.
Keywords:
chlamydia
gonorrhea
dried urine
filter paper
STI testing
genotyping
antimicrobial resistance

Journal

Journal of Clinical Microbiology cover
Journal of Clinical Microbiology
IF:
5.4
Papers:
2.1W
Citations:
4.3W

Organization

B
BC Centre for Disease Control
Scholars:
751
Papers: 458
Citations: 845
P
Public Health Agency of Canada
Scholars:
2.8K
Papers: 2.0K
Citations: 2.2K
M
mcmaster university
Scholars:
4.8K
Papers: 2.0K
Citations: 0
U
university of manitoba
Scholars:
2.1K
Papers: 957
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers