Development and Validation of a Continuous Real-Time Optical Sensor for Indocyanine Green Clearance Measurement During Ex Vivo Perfusion of Human Livers

delete2026-03-01
delete0
PRE
AI
E
Edmund N. J. Derwent
R
Risbey, Charles W. G.
N
Niu, Anita
P
Paul Yousif
N
Nidula Fonseka
C
Chloe Kwok-Long Seow
N
Ng, Isaac
G
Geoffrey W. McCaughan
M
M. Crawford
C
Carlo Pulitanò
D
Daniel Babekuhl *
DOI:10.1111/aor.70114delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Background Liver transplantation remains the only curative treatment for end-stage liver failure, yet its impact is constrained by organ shortages and graft non-utilization. Machine perfusion (MP) enables ex vivo liver assessment; however, current viability criteria rely on intermittent sampling, limiting temporal resolution and accuracy. Indocyanine green (ICG), a clinically validated dye cleared exclusively by hepatocytes, provides a continuous index of hepatic function beyond initial injury.Methods We present a non-invasive, clamp-on optical sensor that demonstrates the first continuous, real-time quantification of ICG clearance during MP. The sensor consists of a clamp-on module with an 808 nm laser and phototransistor connected to a microcontroller and computer for real-time plotting. The raw phototransistor signal was linearised to a unitless absorbance signal proportional to perfusate ICG; bi-exponential fitting yielded plasma disappearance rate (PDRbi, %/min) and the 15-min residual fraction (R15).Results Across 10 whole and 3 split human livers (45 boluses; 13 paired with spectrophotometry), the sensor closely matched spectrophotometric measurements (pooled R2 = 0.994; range 0.983-0.999). The sensor resolved expected physiological trends: ICG clearance rate increased from subnormothermic to normothermic temperatures (Delta PDRbi + 14.41% +/- 9.53%/min, Delta R15 -22.35 +/- 9.97 percentage points; n = 4). The continuous sensor signal also revealed early mixing dynamics and medication-related effects missed by intermittent sampling.Conclusions This optical sensor enables accurate, real-time monitoring of ICG clearance during ex vivo perfusion. The ex vivo setting is uniquely positioned to validate ICG clearance models, enhance clinical interpretation, and support informed graft assessment during perfusion.
Keywords:
biexponential plasma disappearance rate (PDRbi)
indocyanine green (ICG)
liver transplantation
machine perfusion (MP)
optical sensor
plasma disappearance rate (PDR)
retention after 15 min (R15)

Journal

A
ARTIFICIAL ORGANS
IF:
2.3
Papers:
98
Citations:
0

Organization

R
Royal Prince Alfred Hospital
Scholars:
3.3K
Papers: 2.6K
Citations: 5.5K
N
NSW Health
Scholars:
1.9W
Papers: 1.5W
Citations: 12
Cited Papers

Cited Papers

Citing Papers

Citing Papers