1
Return

Development and validation of LC-MS/MS methods for the quantification of TMS-007; a member of the SMTP congeners; in rat plasma and brain: application to a preclinical pharmacokinetic study

delete2026-06-25
delete0
PRE
AI
Y
Yuanbin Hao †
Y
Yan Zhang †
H
Huaye Gao
C
Chenjun Wu
L
Li Sun
S
Siqi Zhao
S
Shaofei Xie *
R
Rong Chen *
DOI:10.1039/D6AY00057Fdelete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
TMS-007 is a member of the SMTP congeners for the treatment of acute ischemic stroke. To support its preclinical study; LC-MS/MS methods for the quantification of TMS-007 in rat plasma and brain were developed. The samples were prepared by protein precipitation. A UPLC HSS T3 column (2.1 mm × 50 mm; 1.8 µm) was used to achieve chromatographic separation. An acetonitrile–water mixture containing ammonium acetate was used as the mobile phase. The methods were validated with regard to selectivity; calibration curve and lower limit of quantitation; accuracy and precision; matrix effect; extraction recovery; carryover; dilution integrity; and stability. The calibration ranges of TMS-007 in rat plasma and brain homogenate were 10.0–10 000 ng mL−1. There was no endogenous or cross interference in the biological matrices. Across these matrices; the intra- and inter-batch coefficients of variation and accuracy deviations for all QC samples met the acceptance criteria. The inter-batch coefficients of variation of the QC samples were ≤11.7% for plasma and ≤15.0% for brain. The inter-batch accuracy ranged from 97.8% to 104.1% for plasma and 97.1% to 102.3% for brain. No significant matrix effect was observed from the matrices (from 102.9% to 111.0% for plasma and from 114.3% to 118.9% for brain). The extraction recoveries of the methods at different concentrations were consistent and reproducible. For plasma; the coefficients of variation were ≤9.9%; and for brain; the coefficients of variation were ≤4.6%. The analyte was stable in different matrices under various storage conditions (room temperature for 8 h; 4 °C in the autosampler for 3 days; 3 freeze–thaw cycles and 7 days at −70 °C). The methods were successfully applied to a preclinical study in a transient middle cerebral artery occlusion rat model after single dose administration. The pharmacokinetic results of the study drug laid a foundation for its further development.

Journal

A
anal. methods
IF:
0
Papers:
382
Citations:
0

Organization

C
china pharmaceutical university
Scholars:
3.0K
Papers: 627
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers