arrow
Return

Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI

delete2020-07-08
delete22
PRE
AI
吴
吴丹 (Dan Wu) *
D
Dapeng Liu
Y
Yi‐Cheng Hsu
H
Haotian Li
Y
Yi Sun
Q
Qin Qin
Y
Yi Zhang
DOI:10.1002/mrm.28401delete
deleteOriginal
deleteShare
deleteSave
Abstract

Abstract

En 中文
Purpose Oscillating gradient (OG) enables the access of short diffusion times for time-dependent diffusion MRI (dMRI); however, it poses several technical challenges for clinical use. This study proposes a 3D oscillating gradient-prepared gradient spin-echo (OGprep-GRASE) sequence to improve SNR and shorten acquisition time for OG dMRI on clinical scanners. Methods The 3D OGprep-GRASE sequence consisted of global saturation, diffusion encoding, fat saturation, and GRASE readout modules. Multiplexed sensitivity-encoding reconstruction was used to correct the phase errors between multiple shots. We compared the scan time and SNR of the proposed sequence and the conventional 2D-EPI sequence for OG dMRI at 30-90-mm slice coverage. We also examined the time-dependent diffusivity changes with OG dMRI acquired at frequencies of 50 Hz and 25 Hz and pulsed-gradient dMRI at diffusion times of 30 ms and 60 ms. Results The OGprep-GRASE sequence reduced the scan time by a factor of 1.38, and increased the SNR by 1.74-2.27 times compared with 2D EPI for relatively thick slice coverage (60-90 mm). The SNR gain led to improved diffusion-tensor reconstruction in the multishot protocols. Image distortion in 2D-EPI images was also reduced in GRASE images. Diffusivity measurements from the pulsed-gradient dMRI and OG dMRI showed clear diffusion-time dependency in the white matter and gray matter of the human brain, using both the GRASE and EPI sequences. Conclusion The 3D OGprep-GRASE sequence improved scan time and SNR and reduced image distortion compared with the 2D multislice acquisition for OG dMRI on a 3T clinical system, which may facilitate the clinical translation of time-dependent dMRI.
Keywords:
3D-GRASE
diffusion-time dependency
oscillating gradient
signal-to-noise ratio | scan time

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

S
siemens ag
Scholars:
5.6K
Papers: 4.6K
Citations: 3
J
Johns Hopkins University
Scholars:
10.2W
Papers: 8.8W
Citations: 13.0W
Z
zhejiang university
Scholars:
17.7W
Papers: 12.1W
Citations: 152
researcher View more organizations
Cited Papers

Cited Papers

Oscillating diffusion-encoding with a high gradient-amplitude and high slew-rate head-only gradient for human brain imaging
err2020-02-03
err23
errOAAI
errTan, Ek T.; Shih, Robert Y.; Mitra, Jhimli; Sprenger, Tim; Hua, Yihe; Bhushan, Chitresh; Bernstein, Matt A.; McNab, Jennifer A.; DeMarco, J. Kevin; Ho, Vincent B.; Foo, Thomas K. F.
errShare
errSave
Fast 3D Chemical Exchange Saturation Transfer (CEST) Imaging of the Human Brain
err2010-08-25
err147
errOAAI
errZhu, He; Jones, Craig K.; van Zijl, Peter C. M.; Barker, Peter B.; Zhou, Jinyuan
errShare
errSave
Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition
err2020-05-13
err28
errOAAI
errLiu, Dapeng; Xu, Feng; Li, Wenbo; van Zijl, Peter C.; Lin, Doris D.; Qin, Qin
errShare
errSave
researcher View more