arrow
Return

Does High Hip Center Decrease Range of Motion in Total Hip Arthroplasty? A Computer Simulation Study

delete2016-10-01
delete51
PRE
AI
K
K. Komiyama
Y
Yasuharu Nakashima *
M
Masanobu Hirata
D
Daisuke Hara
Y
Yusuke Kohno
Y
Yukihide Iwamoto
DOI:10.1016/j.arth.2016.03.014delete
deleteOriginal
deleteShare
deleteSave
Abstract

Abstract

En 中文
Background: High placement of a cementless acetabular cup is often required to have sufficient bone coverage in hip dysplasia. We examined whether a high hip center decreases the postoperative range of motion (ROM) in total hip arthroplasty. Methods: Using a computer software, ROM and bone coverage were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. The cup was placed at the anatomic hip center and moved vertically in 5-mm increments. Vertical center of rotation (V-COR) was defined as the distance from the head center to the interteardrop line. The required ROM was defined as flexion >= 110 degrees, internal rotation (IR) at 90 degrees flexion >= 30 degrees, extension >= 30 degrees, and external rotation >= 30 degrees. We determined the V-COR to satisfy the required ROM and cup center-edge angle (Cup-CE) >= 0 degrees. Results: Only 40.6% of the patients satisfied Cup-CE >= 0 degrees at the anatomic hip center. Bone coverage increased with the peak at 30, 35 mm of V-COR (90.6% satisfied Cup-CE >= 0 degrees) and decreased at >= 40 mm. Higher V-COR resulted in lower range of flexion and IR, but increased the range of extension and external rotation. The cutoff value from the receiver-operating characteristic curve for both flexion and IR was a V-COR of 35 mm. Conclusion: The higher hip center gained more bone coverage but decreased the range of hip flexion and IR. Acceptable V-COR in hip dysplasia was around 35 mm, about 20 mm above the true hip center, in terms of ROM. (C) 2016 Elsevier Inc. All rights reserved.
Keywords:
high hip center
hip dysplasia
range of motion
total hip arthroplasty
computer simulation

Journal

JOURNAL OF ARTHROPLASTY cover
JOURNAL OF ARTHROPLASTY
IF:
3.8
Papers:
1.3W
Citations:
3.3W

Organization

K
kyushu university
Scholars:
1.4K
Papers: 459
Citations: 4.1K
Cited Papers

Cited Papers

Design Aspects, Challenges and Benefits of SiC-Based Integrated Switched Reluctance Machine Drives
err2022-10-09
err0
PREAI
errMd Ehsanul Haque; Anik Chowdhury; Mohammad Arifur Rahman; Shuvajit Das; Abdul Wahab Bandarkar; Md Tawhid Bin Tarek; Okan Boler; Yilmaz Sozer; Ashraf Siddiquee; Jeffrey Geither; David Colavincenzo; Fernando Venegas
errShare
errSave
Association of High-Sensitivity Troponin T With Left Ventricular Dysfunction in Ankylosing Spondylitis
err2018-11-09
err0
PREAI
errSerdar Turkmen; Lutfu Askin; Kader Eliz Uzel; Huseyin Nacar; Veysi Kavalci; Erdal Akturk; Mustafa Yavuz Selçuk
errShare
errSave
errShare
errSave
Effect of Thirst-Driven Fluid Intake on 1 H Cycling Time-Trial Performance in Trained Endurance Athletes
err2019-10-14
err0
errOAAI
errMaxime Perreault-Briere; Jeff Beliveau; David Jeker; Thomas A. Deshayes; Ana Duran; Eric D. B. Goulet
errShare
errSave
researcher View more