arrow
Return

Dynamic resonant frequency tracking and synchronization for induction heating using half-cycle measurement algorithm

delete2025-10-30
delete0
delete
OA
AI
U
Umar Tabrez Shami
T
Tabrez Aslam Shami
A
Ali Faisal Murtaza
A
Abdulrahman Alsafrani *
DOI:10.1016/j.egyr.2025.10.032delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
This research paper presents a dynamic feedback control algorithm designed to continuously track and maintain the resonant frequency in induction heating systems. The research paper begins by introducing a theoretical framework for the dynamic algorithm that enables real-time measurement of the resonant frequency. The proposed method removes the necessity for frequency sweeps or time delays commonly used in tracking and synchronization. The dynamics of achieving resonant frequency synchronization are examined as variations in induction load characteristics—such as changes in temperature and material properties—alter the system, thereby causing corresponding shifts in the resonant frequency. The proposed system for tracking and synchronizing with resonant frequency consists of a combination of hardware and software components. The hardware consists of a full-bridge resonant inverter connected to an RLC tank circuit, along with a microcontroller-based feedback system designed to monitor, measure, and synchronize the resonant frequency. The proposed feed-back control algorithm, implemented as a software component in the microcontroller, determines the instantaneous half-cycle duration of each individual resonant frequency voltage signal and regulates the resonant inverter's switching frequency to match this duration. Comprehensive simulation and laboratory tests were carried out to evaluate the proposed induction heating system. These tests included trials under both no-load and various load conditions to assess the system’s performance, response accuracy, and robustness. Additionally, the efficiency of the induction heating system was determined experimentally. Satisfactory results of the experiments validated the effectiveness of the proposed frequency tracking system.
Keywords:
Algorithm
Energy Converter
Induction Heating Systems
Full-Bridge Resonant Inverter
Microcontroller Digital Circuit
RLC Tank Circuit
Resonant Frequency Tracking and Synchronization
Variable Induction Heating Load
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

E
Energy Reports
IF:
5.1
Papers:
763
Citations:
0

Organization

U
university of engineering and technology
Scholars:
553
Papers: 304
Citations: 0
Q
Qassim University
Scholars:
5.6K
Papers: 5.4K
Citations: 5.0K