arrow
Return

Dynamic Resource Allocation for Real-Time Priority Processing Applications

delete2010-05-01
delete8
delete
OA
AI
M
Martijn M. H. P. van den Heuvel *
R
Reinder J. Bril
S
Stefan Schiemenz
C
Christian Hentschel
DOI:10.1109/TCE.2010.5506015delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Flexible signal processing on programmable platforms are increasingly important for consumer electronic applications and others. Scalable video algorithms (SVAs) using novel priority processing can guarantee real-time performance on programmable platforms even with limited resources. Dynamic resource allocation is required to maximize the overall output quality of independent, competing priority processing algorithms that are executed on a shared platform. In this paper, we describe basic mechanisms for dynamic resource allocation and compare the performance of different implementations on a general purpose platform(1).
Keywords:
priority processing
scalable video algorithms
dynamic resource allocation
preliminary termination
monitoring

Journal

IEEE Transactions on Consumer Electronics cover
IEEE Transactions on Consumer Electronics
IF:
10.9
Papers:
5.1K
Citations:
6.8K

Organization

B
brandenburg university of technology cottbus
Scholars:
1.8K
Papers: 1.6K
Citations: 1
E
Eindhoven University of Technology
Scholars:
1.6W
Papers: 1.5W
Citations: 2.2W
Cited Papers

Cited Papers

Endovascular Mechanical Thrombectomy of an Occluded Superior Division Branch of the Left MCA for Acute Cardioembolic Stroke
err2003-06-01
err0
PREAI
errH. C. Schumacher; P. M. Meyers; D. R. Yavagal; N. Y. Harel; M. S. V. Elkind; J. P. Mohr; J. Pile-Spellman
errShare
errSave
The posterior ligament of the incus (“white dot”): A reliable surgical landmark for the facial recess
err2022-03-01
err0
PREAI
errRyan A. McMillan; Ashley M. Nassiri; Luciano C. Leonel; Natalia C. Rezende; Maria Peris Celda; Alex D. Sweeney; Matthew L. Carlson
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
errShare
errSave
Three-dimensional dose comparison of flattening filter (FF) and flattening filter-free (FFF) radiation therapy by using NIPAM gel dosimetry
err2019-02-21
err0
errOAAI
errChun-Hsu Yao; Tung-Hao Chang; Chia-Chi Lin; Yuan-Chun Lai; Chin-Hsing Chen; Yuan-Jen Chang
errShare
errSave
An Environmental-Sensitive BODIPY®-Derivative with Bioapplication: Spectral and Photophysical Properties
err2003-09-01
err0
PREAI
errMikael Isaksson; Stanislav Kalinin; Sergei Lobov; Tor Ny; Lennart B.-Å. Johansson
errShare
errSave
no more