1
Return

Early Safety and Feasibility Study of a Novel Transcatheter Aortic Valve With Polymeric Leaflets

delete2026-04-01
delete1
PRE
AI
Z
Zhang, Xiaochun
Q
Qinchun Jin
W
Wenzhi Pan
W
Wei Li
B
Bin Wang
Y
Yan Wang
H
Hongbo Yang
D
Da Zhu
X
Xiang Bin Pan
L
Li, Bo
S
Shasha Chen
Y
Yuliang Long
Z
Zhang, Lei
R
Ren, Yun
H
Haiyan Chen
Y
Yang, Xue
J
J Qian
D
Daxin Zhou
G
Ge, Junbo
DOI:10.1016/j.jacasi.2025.10.032delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BACKGROUND Transcatheter aortic valve replacement is a promising alternative treatment for patients with severe aortic stenosis (AS), but uncertainties remain regarding its long-term durability. OBJECTIVES This study aimed to evaluate the safety and feasibility of Sikelia transcatheter heart valve with polymeric leaflets in AS. METHODS In this first-in-human, prospective, nonrandomized, single-arm, multicenter study, patients with severe symptomatic AS eligible for the novel valve were recruited. Clinical outcomes and hemodynamic performance were reported at discharge and 30-day, 6-month, and 1-year follow-up. RESULTS Twelve patients (73.75 f 7.28 years, 25% female, mean Society of Thoracic Surgeons score 4.51% [4.07%-4.87%], 66.67% bicuspid valve) were enrolled. Procedural success was achieved in 83.33% (1 fully device retrieval and 1 death due to coronary obstruction). All patients successfully underwent transcatheter aortic valve replacement were in NYHA functional class I/II at the 30-day follow-up, and significant improvement was shown in 6-minute walk distance and Kansas City Cardiomyopathy Questionnaire score (all P < 0.001). At 1 year, the effective orifice area (2.31 f 0.33 cm2 vs 0.82 f 0.14 cm2) and mean pressure gradient (6.33 f 2.54 mm Hg vs 47.50 f 13.82 mm Hg) improved substantially, so did those in bicuspid patients (all P < 0.001). No moderate/severe paravalvular leakage was recorded, and computed tomography scans revealed no evidence of subclinical leaflet thrombosis during follow-up. After discharge, no patients reported death, stroke, new pacemakers, or valve-related reintervention. CONCLUSIONS The preliminary outcomes of the novel transcatheter heart valve demonstrated a favorable hemodynamic performance with an acceptable safety profile at 1 year. Long-term follow-up is warranted to assess its durability in treating patients with AS. (JACC Asia. 2026;6:465-473) (c) 2026 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Keywords:
aortic stenosis
polymeric leaflets
Sikelia
transcatheter heart valve

Journal

J
JACC-ASIA
IF:
0
Papers:
148
Citations:
0

Organization

F
fudan university
Scholars:
11.3W
Papers: 7.6W
Citations: 121
P
peking union medical college
Scholars:
1.2K
Papers: 607
Citations: 6
K
kunming medical university
Scholars:
1.2W
Papers: 5.6K
Citations: 11
X
xiamen university
Scholars:
5.7W
Papers: 3.7W
Citations: 67
Cited Papers

Cited Papers

Citing Papers

Citing Papers