1
Return

Effect of Device Size on Outcomes Following Left Atrial Appendage Closure in Borderline-Sized Anatomy

delete2026-04-01
delete3
PRE
AI
K
Kensuke IgarashiTomohiko Kuwabara *
S
Shunsuke Kubo
T
Takashi Matsumoto
F
Fukunaga, Masato
Y
Yusuke Kondo
S
Sugane, Hiroki
K
Kenji Okubo
K
Koji Nakagawa
D
Daisuke Nagatomo
D
Daisuke Hachinohe
S
Shigeki Kusa
T
Tomoyuki Umemoto
M
Mamoru Nanasato
T
Takeshi Arita
H
Hiro Yamasaki
T
Tomotaka Yoshiyama
N
Nobuaki Tanaka
M
Masuda, Masaharu
T
Tomohiro Sakamoto
M
Masaki Nakashima
Y
Yohei Ohno
S
Shigeru Saito
H
Hara, Hidehiko
DOI:10.1016/j.jacasi.2025.11.015delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BACKGROUND Selecting the optimal WATCHMAN FLX (a second-generation left atrial appendage [LAA] closure device) size for a borderline-sized LAA, for which 2 device sizes are acceptable, remains challenging. OBJECTIVES The aim of this study was to evaluate how device size affects procedural and clinical outcomes in borderline-sized LAAs undergoing LAA closure. METHODS From the Japanese multicenter TERMINATOR (Transcatheter Modification of Left Atrial Appendage by Obliteration with Device in Patients With NVAF) registry, 1,190 patients who underwent LAA closure with the second-generation device between May 2021 and September 2023 were reviewed. Of these, 757 with borderline-sized LAAs were included and categorized into large (n = 390) and small (n = 367) device groups. The median follow-up duration was 274 days (Q1-Q3: 100-368 days). Outcomes included peridevice leak (PDL), all-cause mortality, ischemic cerebrovascular accident or systemic embolism, major bleeding, and device-related thrombus. RESULTS PDL occurred less frequently in the large device group compared with the small device group (1.54% [6 of 390] vs 4.90% [18/367]; P = 0.015). Ischemic cerebrovascular accident or systemic embolism was lower in the large device group (8.4% [95% CI: 1.8%-34.1%] vs 10.5% [95% CI: 3.6%-28.4%]; P = 0.036). No significant difference was observed in all-cause mortality (15.2% [95% CI: 6.0%-35.7%] vs 12.3% [95% CI: 4.6%-30.6%]; P = 0.288), major bleeding (4.5% [95% CI: 2.6%-7.7%] vs 15.7% [95% CI: 4.3%-48.7%]; P = 0.570), or device-related thrombus (8.6% [95% CI: 3.2%-22.2%] vs 3.2% [95% CI: 1.6%-6.4%]; P = 0.603). CONCLUSIONS In borderline-sized LAAs, the larger device was associated with fewer PDLs and ischemic events without increased procedural risk. (JACC Asia. 2026;6:477-489) (c) 2026 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Keywords:
atrial fibrillation
ischemic stroke
left atrial appendage closure
peridevice leak

Journal

J
JACC-ASIA
IF:
0
Papers:
148
Citations:
0

Organization

K
kurashiki central hospital
Scholars:
316
Papers: 153
Citations: 10
S
Saiseikai Kumamoto Hospital
Scholars:
436
Papers: 408
Citations: 291
U
university of tsukuba
Scholars:
2.9K
Papers: 1.1K
Citations: 0
K
Kokura Memorial Hospital
Scholars:
639
Papers: 661
Citations: 146
C
chiba university
Scholars:
2.4K
Papers: 802
Citations: 0
T
tsuchiura kyodo hospital
Scholars:
518
Papers: 327
Citations: 0
T
Tokai University
Scholars:
5.7K
Papers: 4.7K
Citations: 3.9K
K
Kansai Rosai Hospital
Scholars:
800
Papers: 704
Citations: 333
I
institute of science tokyo
Scholars:
2.6K
Papers: 1.0K
Citations: 0
O
osaka metropolitan university
Scholars:
1.7K
Papers: 636
Citations: 0
O
Okayama University
Scholars:
1.6W
Papers: 1.1W
Citations: 8.4K
T
Toho University
Scholars:
5.0K
Papers: 3.8K
Citations: 2.4K
Iwate Medical University cover
Iwate Medical University
Scholars:
368
Papers: 163
Citations: 1.5K
S
Sendai Kousei Hospital
Scholars:
422
Papers: 458
Citations: 253
Cited Papers

Cited Papers

Citing Papers

Citing Papers