Return
Enhanced Single-Phase Phase Locked Loop Based on Complex-Coefficient Filter
DOI:10.1109/TIM.2022.3147891.png)
Abstract
En 中文
Complex coefficient filters (CCFs) are widely used for phase-locked loop (PLL) in three-phase power systems, while its usage is largely sparse in the single-phase domain. Single-phase CCF-PLLs so far reported in the literature do not yield satisfactory performances at off-nominal frequency conditions, which is a crucial PLL attribute. Whether they are a suitable filtering technique of choice for single-phase PLL is yet to be formally documented in a methodological way. In this regard, this article derives an enhanced version of the single-phase CCF-PLL (ECCF-PLL), which is able to provide accurate estimation of grid parameters in dynamically changing grid frequency environment. The proposed ECCF-PLL is then numerically and experimentally compared with few other single-phase PLLs to gauge its efficacy and suitability. The test shows the advantage of harmonic robustness from ECCF-PLL, which is specifically useful in a weak grid.
Keywords:
Phase locked loops
Power harmonic filters
Attenuation
Band-pass filters
Frequency measurement
Synchronization
Harmonic analysis
Complex coefficient filter (CCF)
grid interconnection
phase locked loop (PLL)
single-phase system
synchronization
Journal