• Seventeen micro-pillar surfaces were tested for vertical immersion cooling. • Gradient arrays passively mitigated vapor accumulation on vertical surfaces. • Slender pillars reduced bubble departure diameter and bubble trapping. • Favorable length and spacing gradients enhanced boiling heat transfer performance compared with uniform arrays. • A critical heat flux correlation described the tested surfaces with deviations within ± 5%.