arrow
Return

Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

delete2014-11-01
delete40
PRE
AI
N
Nikhil G. Thaker
R
Rajat J. Kudchadker
D
David A. Swanson
J
Jeffrey M. Albert
U
Usama Mahmood
T
Thomas J. Pugh
N
Nicholas S. Boehling
T
Teresa L. Bruno
B
Bradley R. Prestidge
J
Juanita Crook
B
Brett Cox
L
Louis Potters
B
Brian J. Moran
M
Mira Keyes
D
Deborah A. Kuban
S
Steven J. Frank *
DOI:10.1016/j.ijrobp.2014.06.036delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ((125) I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parameters were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB. (C) 2014 Elsevier Inc.
Keywords:
LEARNING-CURVE
SKILLS CURRICULUM
AMERICAN-COLLEGE
PERMANENT
CANCER
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

I
International Journal of Radiation Oncology Biology Physics
IF:
6.5
Papers:
4.8W
Citations:
4.2W

Organization

U
utmd anderson cancer center
Scholars:
3.0W
Papers: 2.4W
Citations: 27
B
banner research
Scholars:
1.3K
Papers: 1.0K
Citations: 2
B
Banner Health
Scholars:
1.1K
Papers: 741
Citations: 344
N
Northwell Health
Scholars:
1.3W
Papers: 9.6K
Citations: 5.1K
U
university of texas system
Scholars:
18.5W
Papers: 15.6W
Citations: 210
researcher View more organizations