Return
Experimental study on battery thermal management using low temperature solid-solid metal phase change material
DOI:10.1016/j.ijheatmasstransfer.2025.127959.png)
Abstract
En 中文
• BTM with low temperature metal solid-solid metal PCM is proposed. • Tmax of battery module with 4 mm SS-MPCM is below 45°C at 3 C-rate. • BTM with SS-MPCM is even better at higher discharge rates. • Volumetric energy density of the battery module is reduced by 14.75%.
Journal
IF:
5.8
Papers:
2.6W
Citations:
10.2W