Fast quantitative MRI using controlled saturation magnetization transfer

delete2018-09-14
delete46
delete
OA
AI
R
Rui Pedro A. G. Teixeira *
S
Shaihan Malik
J
Joseph V. Hajnal
DOI:10.1002/mrm.27442delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose: This study demonstrates magnetization transfer (MT) effects directly affect relaxometry measurements and develops a framework that allows single-pool models to be valid in 2-pool MT systems. Methods: A theoretical framework is developed in which a 2-pool MT system effectively behaves as a single-pool if the RMS RF magnetic field (B-1(rms)) is kept fixed across all measurements. A practical method for achieving controlled saturation magnetization transfer (CSMT) using multiband RF pulses is proposed. Numerical, Phantom, and in vivo validations were performed directly comparing steady state (SS) estimation approaches that under correct single-pool assumptions would be expected to vary in precision but not accuracy. Results: Numerical simulations predict single-pool estimates obtained from MT model generated data are not consistent for different SS estimation methods, and a systematic underestimation of T-2 is expected. Neither effect occurs under the proposed CSMT approach. Both phantom and in vivo experiments corroborate the numerical predictions. Experimental data highlights that even when using the same relaxometry method, different estimates are obtained depending on which combination of flip angles (FAs) and TRs are used if the CSMT approach is not used. Using CSMT, stable measurements of both T-1 and T-2 are obtained. The measured T-1 (T-1(CSMT))) depends on B-1(rms), which is therefore an important parameter to specify. Conclusion: This work demonstrates that conventional single pool relaxometry, which is highly efficient for human studies, results in unreliable parameter estimates in biological tissues because of MT effects. The proposed CSMT framework is shown to allow single-pool assumptions to be valid, enabling reliable and efficient quantitative imaging to be performed.
Keywords:
DESPOT
JSR
MT
relaxometry
steady-state
VFA
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

U
university of london
Scholars:
21.5W
Papers: 19.7W
Citations: 305