arrow
Return

Feasibility study of PET dynamic imaging of [18F]DHMT for quantification of reactive oxygen species in the myocardium of large animals

delete2022-02-01
delete8
delete
OA
AI
吴婧 (Jing Wu)
N
Nabil E. Boutagy
Z
Zhengxin Cai
S
Shu-fei Lin
M
Ming‐Qiang Zheng
A
Attila Fehér
J
John C. Stendahl
M
Michael Kapinos
J
Jean‐Dominique Gallezot
刘辉 (Hui Liu)
W
Wenjie Zhang
M
Marcel Lindemann
J
Jo-ku Teng
E
Edward J. Miller
Y
Yiyun Huang
R
Richard E. Carson
A
Albert J. Sinusas
C
Chi Liu *
DOI:10.1007/s12350-020-02184-3delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Objectives We aimed to develop a dynamic imaging technique for a novel PET superoxide tracer, [F-18]DHMT, to allow for absolute quantification of myocardial reactive oxygen species (ROS) production in a large animal model. Methods Six beagle dogs underwent a single baseline dynamic [F-18]DHMT PET study, whereas one animal underwent three serial dynamic studies over the course of chronic doxorubicin administration (1 mg center dot kg(-1)center dot week(-1) for 15 weeks). During the scans, sequential arterial blood samples were obtained for plasma metabolite correction. The optimal compartment model and graphical analysis method were identified for kinetic modeling. Values for the left ventricular (LV) net influx rate, K-i, were reported for all the studies and compared with the LV standard uptake values (SUVs) and the LV-to-blood pool SUV ratios from the 60 to 90 minute static images. Parametric images were also generated. Results [F-18]DHMT followed irreversible kinetics once oxidized within the myocardium in the presence of superoxide, as evidenced by the fitting generated by the irreversible two-tissue (2Ti) compartment model and the linearity of Patlak analysis. Myocardial K-i values showed a weak correlation with LV SUV (R-2 = 0.27), but a strong correlation with LV-to-blood pool SUV ratio (R-2 = 0.92). Generation of high-quality parametric images showed superior myocardial to blood contrast compared to static images. Conclusions A dynamic PET imaging technique for [F-18]DHMT was developed with full and simplified kinetic modeling for absolute quantification of myocardial superoxide production in a large animal model.
Keywords:
Reactive oxygen species (ROS)
positron emission tomography (PET)
kinetic modeling
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.