arrow
Return

Flexible numerical simulation framework for dynamic PET-MR data

delete2020-07-21
delete4
delete
OA
AI
J
Johannes Mayer *
R
Richard Brown
K
Kris Thielemans
E
Evgueni Ovtchinnikov
E
Edoardo Pasca
D
David Atkinson
A
Ashley Gillman
P
Paul Marsden
M
Matteo Ippoliti
M
Marcus R. Makowski
T
Tobias Schaeffter
C
Christoph Kolbitsch
DOI:10.1088/1361-6560/ab7eeedelete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
This paper presents a simulation framework for dynamic PET-MR. The main focus of this framework is to provide motion-resolved MR and PET data and ground truth motion information. This can be used in the optimisation and quantitative evaluation of image registration and in assessing the error propagation due to inaccuracies in motion estimation in complex motion-compensated reconstruction algorithms. Contrast and tracer kinetics can also be simulated and are available as ground truth information. To closely emulate medical examination, input and output of the simulation are files in standardised open-source raw data formats. This enables the use of existing raw data as a template input and ensures seamless integration of the output into existing reconstruction pipelines. The proposed framework was validated in PET-MR and image registration applications. It was used to simulate a FDG-PET-MR scan with cardiac and respiratory motion. Ground truth motion information could be utilised to optimise parameters for PET and synergistic PET-MR image registration. In addition, a free-breathing dynamic contrast enhancement (DCE) abdominal scan of a patient with hepatic lesions was simulated. In order to correct for breathing motion, a motion-corrected image reconstruction scheme was used and a Toft's model was fit to the DCE data to obtain quantitative DCE-MRI parameters. Utilising the ground truth motion information, the dependency of quantitative DCE-MR images on the accuracy of the motion estimation was evaluated. We demonstrated that respiratory motion had to be available with an average accuracy of at least the spatial resolution of the DCE-MR images in order to ensure an improvement in lesions visualisation and quantification compared to no motion correction. The proposed framework provides a valuable tool with a wide range of scientific PET and MR applications and will be available as part of the open-source project Synergistic Image Reconstruction Framework (SIRF).
Keywords:
PET-MR
motion correction
simulation
image registration
open source

Journal

Physics in Medicine and Biology cover
Physics in Medicine and Biology
IF:
3.4
Papers:
1.4W
Citations:
3.1W

Organization

U
University College London
Scholars:
7.9W
Papers: 6.2W
Citations: 15.7W
S
STFC Rutherford Appleton Laboratory
Scholars:
3.3K
Papers: 2.1K
Citations: 11
P
physikalisch-technische bundesanstalt (ptb)
Scholars:
2.1K
Papers: 1.6K
Citations: 0
S
science & technology facilities council (stfc)
Scholars:
4.6K
Papers: 3.3K
Citations: 8
U
uk research & innovation (ukri)
Scholars:
2.7W
Papers: 2.3W
Citations: 32
U
university of london
Scholars:
21.5W
Papers: 19.7W
Citations: 305
researcher View more organizations