arrow
Return

Harmonic reducer converter

delete2003-04-01
delete16
PRE
AI
O
O. García *
M
Martínez-Avial, MD
J
J.A. Cobos
J
J. Uceda
G
González, J
DOI:10.1109/TIE.2003.809388delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
A new strategy to accomplish low-frequency Regulation EN 61000-3-2 at system level is proposed in this paper. By means of a simple converter, connected in parallel with the loads, the harmonic currents generated by them are greatly reduced, it being unnecessary to include additional power-factor-correction converters. This approach is based on the well-known parallel active power filters, but the difference is that it is placed on the dc side. Its position, at the rectified line voltage, produces some important advantages such as a simple power stage, a simple analog control, and flexibility in the design of the system. Moreover, this converter features high efficiency and small size. The experimental results show the benefits of this solution.