arrow
Return

Improving CBCT quality to CT level using deep learning with generative adversarial network

delete2021-05-14
delete86
delete
OA
AI
Y
Yang Zhang
N
Ning J. Yue
M
Min‐Ying Su
B
Bo Liu
Y
Yi Ding
Y
Yongkang Zhou
H
Hao Wang
Y
Yu Kuang
K
Ke Nie *
DOI:10.1002/mp.14624delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose: To improve image quality and computed tomography (CT) number accuracy of daily cone beam CT (CBCT) through a deep learning methodology with generative adversarial network. Methods: One hundred and fifty paired pelvic CT and CBCT scans were used for model training and validation. An unsupervised deep learning method, 2.5D pixel-to-pixel generative adversarial network (GAN) model with feature mapping was proposed. A total of 12 000 slice pairs of CT and CBCT were used for model training, while ten-fold cross validation was applied to verify model robustness. Paired CT-CBCT scans from an additional 15 pelvic patients and 10 head-and-neck (HN) patients with CBCT images collected at a different machine were used for independent testing purpose. Besides the proposed method above, other network architectures were also tested as: 2D vs 2.5D; GAN model with vs without feature mapping; GAN model with vs without additional perceptual loss; and previously reported models as U-net and cycleGAN with or without identity loss. Image quality of deep-learning generated synthetic CT (sCT) images was quantitatively compared against the reference CT (rCT) image using mean absolute error (MAE) of Hounsfield units (HU) and peak signal-to-noise ratio (PSNR). The dosimetric calculation accuracy was further evaluated with both photon and proton beams. Results: The deep-learning generated sCTs showed improved image quality with reduced artifact distortion and improved soft tissue contrast. The proposed algorithm of 2.5 Pix2pix GAN with feature matching (FM) was shown to be the best model among all tested methods producing the highest PSNR and the lowest MAE to rCT. The dose distribution demonstrated a high accuracy in the scope of photon-based planning, yet more work is needed for proton-based treatment. Once the model was trained, it took 11-12 ms to process one slice, and could generate a 3D volume of dCBCT (80 slices) in less than a second using a NVIDIA GeForce GTX Titan X GPU (12 GB, Maxwell architecture). Conclusion: The proposed deep learning algorithm is promising to improve CBCT image quality in an efficient way, thus has a potential to support online CBCT-based adaptive radiotherapy. (C) 2020 American Association of Physicists in Medicine.
Keywords:
adaptive radiotherapy
CBCT
deep learning
GAN
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Medical Physics cover
Medical Physics
IF:
3.2
Papers:
3.7W
Citations:
3.2W

Organization

R
rutgers university new brunswick
Scholars:
2.3W
Papers: 1.9W
Citations: 32
R
rutgers university system
Scholars:
4.1W
Papers: 3.7W
Citations: 53
R
rutgers university biomedical & health sciences
Scholars:
6.3K
Papers: 5.0K
Citations: 7
University of California System cover
University of California System
Scholars:
37.5W
Papers: 33.7W
Citations: 6.6K
R
Rutgers Cancer Institute of New Jersey
Scholars:
1.1K
Papers: 847
Citations: 2.6K
U
university of california irvine
Scholars:
2.3W
Papers: 1.7W
Citations: 55
researcher View more organizations