arrow
Return

Indoor Lighting Customization Based on Effective Reflectance Coefficients: A Methodology to Optimize Visual Performance and Decrease Consumption in Educative Workplaces

delete2020-12-24
delete8
delete
OA
AI
A
Antonio Peña-García *
F
Ferdinando Salata
DOI:10.3390/su13010119delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
The importance of accurate lighting has been proven to be essential for good performance in all kinds of buildings, where most of the professional activities are carried out. National regulations and international standards dealing with indoor lighting establish the technical requirements of lighting installations to ensure the performance of their users. These requirements deal with illuminance on the working plane, uniformity, glare, color temperature of light and some other parameters. However, regulations and technical documents on indoor lighting are mainly referred to standard conditions that are sometimes far away from the reality. Hence, some installations can fulfill the technical requirements, whilst being uncomfortable for task development, impairing user's performance and are oversized in terms of energy consumption. This work departs from a field study in highlighting the regulatory limitations in the matter of reflectance, to propose a quasi-Lambertian approach to real conditions in indoor workplaces with a special aim in educative environments. It consists of the introduction of effective reflectance coefficients for some key visual tasks and furniture carried out by users in certain typical positions and working planes. Based on this coefficient, it is proposed to implement a simple measurement and luminary programming methodology adapted to each particular workplace, especially in educational centers. The final target is to improve visual performance and save energy.
Keywords:
indoor lighting
energy savings
workplaces
efficient buildings
visual comfort
visual performance

Journal

Sustainability cover
Sustainability
IF:
3.3
Papers:
10.8W
Citations:
36.8W

Organization

U
University of Granada
Scholars:
620
Papers: 266
Citations: 1.0W
S
sapienza university rome
Scholars:
6.3W
Papers: 4.7W
Citations: 4.8W
Cited Papers

Cited Papers

A new optimal light sensor placement method of an indoor lighting control system for improving energy performance and visual comfort
err2020-07-01
err31
PREAI
errWagiman, Khairul Rijal; Abdullah, Mohd Noor; Hassan, Mohammad Yusri; Radzi, Nur Hanis Mohammad
errShare
errSave
errShare
errSave
A proposed lighting-design space: circadian effect versus visual illuminance
err2017-09-01
err58
PREAI
errDai, Qi; Cai, Wenjing; Shi, Wen; Hao, Luoxi; Wei, Minchen
errShare
errSave
errShare
errSave
The impact of room surface reflectance on corneal illuminance and rule-of-thumb equations for circadian lighting design
err2018-08-01
err59
errOAAI
errCai, Wenjing; Yue, Jiguang; Dai, Qi; Hao, Luoxi; Lin, Yi; Shi, Wen; Huang, Yingying; Wei, Minchen
errShare
errSave
Influence of undersized cementless hip stems on primary stability and strain distribution
err2017-09-01
err0
PREAI
errAndreas Fottner; Matthias Woiczinski; Manuel Kistler; Christian Schröder; Tobias F. Schmidutz; Volkmar Jansson; Florian Schmidutz
errShare
errSave
Femoral revision with the Wagner tapered stem
err2011-10-01
err0
PREAI
errD. Regis; A. Sandri; I. Bonetti; M. Braggion; P. Bartolozzi
errShare
errSave
researcher View more