arrow
Return

Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon-in-Basket Pulsed Field Ablation

delete2025-12-01
delete1
delete
OA
AI
J
Jan‐Per Wenzel
S
Sascha Hatahet *
C
Charlotte Eitel
R
Raed Abdessadok
S
S S Popescu
J
Julius Nikorowitsch
S
Suzanne de Waha
T
Tanja Zeller
K
Karl‐Heinz Kück
R
Roland Richard Tilz
DOI:10.1111/jce.70221delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Background Cryoballoon ablation (CB) is a well-established thermal technique for pulmonary vein isolation (PVI), while balloon-in-basket pulsed field ablation (BiB-PFA) represents a novel non-thermal alternative. Both single-shot systems may trigger systemic inflammation and myocardial injury, yet direct comparisons are lacking. This study aimed to compare inflammatory and myocardial biomarker responses following first-time PVI using CB or BiB-PFA.Methods In this prospective, single-center study, 100 patients undergoing PVI for symptomatic paroxysmal or persistent atrial fibrillation (AF) were enrolled (CB: n = 50; BiB-PFA: n = 50). Venous blood samples were collected before and on the morning after ablation to assess leukocytes, C-reactive protein (CRP), platelets, troponin T, creatine kinase (CK), myoglobin, creatinine, and estimated glomerular filtration rate. Baseline characteristics, procedural data, and acute success were analyzed.Results Patients in the CB group were older (74 vs. 65 years; p = 0.01) and had higher CHA(2)DS(2)-VAcore (3.0 vs. 2.0; p = 0.009). Acute PVI was achieved in all cases CB was associated with greater increases in leukocytes (Delta 2.5 vs. 1.1 x 10(9)/L; p = 0.05) and CRP (Delta 5.8 vs. 3.4 mg/L; p = 0.02), whereas BiB-PFA showed higher rises in CK (Delta 217 vs. 103 U/L; p = 0.01) and troponin T (Delta 1129 vs. 614.5 ng/L; p = 0.01). No significant correlation was found between energy delivery and biomarker changes.Conclusion CB and BiB-PFA elicit distinct systemic responses. CB provoked stronger inflammatory activation, while BiB-PFA caused greater myocardial biomarker release, suggesting energy- and device-specific effects.
Keywords:
atrial fibrillation
catheter design
cryoballoon
inflammation
myocardial injury
platelets
pulmonary vein isolation
pulsed field ablation
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Journal of Cardiovascular Electrophysiology cover
Journal of Cardiovascular Electrophysiology
IF:
2.6
Papers:
284
Citations:
9.0K

Organization

U
university of kiel
Scholars:
2.3W
Papers: 1.7W
Citations: 15
S
schleswig holstein university hospital
Scholars:
7.5K
Papers: 5.4K
Citations: 5