Influence of extraction distribution volume on dust control as enabled by a negative-pressure double-extraction system

delete2026-08-12
delete0
PRE
AI
聂闻 (Wen Nie)
S
Shihao Liu
C
Chuanxing Cheng
Q
Qiang Liu *
DOI:10.1016/j.tust.2026.108017delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
To reduce dust pollution from tunnel boring, we constructed a negative-pressure double-pumping ventilation control and dust removal system. We used a combination of numerical simulations and onsite measurements. The system reduced the overall dust concentration in the tunnel and the dust concentration in the operation area of the roadheader driver. The average dust concentration in the tunnel was 126.17 mg/m3 (improvement: 70.66%), and that at the driver of the roadheader was <131.82 mg/m3 (improvement: 68.61%). The optimal air extraction volume (QA) of extraction cylinder A (CA) was 100 m3/min, and the optimal air extraction volume (QB) of extraction cylinder B (CB) was 300 m3/min. We verified the accuracy of the numerical simulations by combining with onsite measurements, and in so doing have provided new ideas and methods for dust management in the working face of the comprehensive excavation face.
Keywords:
Tunnel excavation
Dust control system
Dust
Air purification
Occupational health

Journal

Tunnelling and Underground Space Technology cover
Tunnelling and Underground Space Technology
IF:
7.4
Papers:
6.8K
Citations:
3.5W

Organization

S
shandong university of science and technology
Scholars:
1.8K
Papers: 588
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers