arrow
Return

Integrated multiple patch-clamp array chip via lateral cell trapping junctions

delete2004-03-15
delete119
PRE
AI
J
Jiwon Seo
C
Cristian Ionescu‐Zanetti
J
Jordan Diamond
R
Ratnesh Lal
L
L. P. Lee
DOI:10.1063/1.1650035delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
We present an integrated multiple patch-clamp array chip by utilizing lateral cell trapping junctions. The intersectional design of a microfluidic network provides multiple cell addressing and manipulation sites for efficient electrophysiological measurements at a number of patch sites. The patch pores consist of openings in the sidewall of a main fluidic channel, and a membrane patch is drawn into a smaller horizontal channel. This device geometry not only minimizes capacitive coupling between the cell reservoir and the patch channel, but also allows simultaneous optical and electrical measurements of ion channel proteins. Evidence of the hydrodynamic placement of mammalian cells at the patch sites as well as measurements of patch sealing resistance is presented. Device fabrication is based on micromolding of polydimethylsiloxane, thus allowing inexpensive mass production of disposable high-throughput biochips. (C) 2004 American Institute of Physics.
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Applied Physics Letters cover
Applied Physics Letters
IF:
3.6
Papers:
10.4W
Citations:
17.8W

Organization

No organization information available
Cited Papers

Cited Papers

Structure formation at the interface of liquid liquid bilayer in electric field
err2002-04-04
err164
PREAI
errLin, ZQ; Kerle, T; Russell, TP; Schäffer, E; Steiner, U
errShare
errSave
Stable integration of isolated cell membrane patches in a nanomachined aperture
err2000-08-21
err85
PREAI
errFertig, N; Tilke, A; Blick, RH; Kotthaus, JP; Behrends, JC; ten Bruggencate, G
errShare
errSave
Activity of single ion channel proteins detected with a planar microstructure
err2002-12-16
err122
PREAI
errFertig, N; Klau, M; George, M; Blick, RH; Behrends, JC
errShare
errSave
Whole cell patch clamp recording performed on a planar glass chip
err2002-06-01
err341
errOAAI
errFertig, N; Blick, RH; Behrends, JC
errShare
errSave
errShare
errSave
errShare
errSave
Ion-channel assay technologies:: quo vadis?
err2001-12-01
err179
PREAI
errXu, J; Wang, XB; Ensign, B; Li, M; Wu, L; Guia, A; Xu, JQ
errShare
errSave
no more