1
Return

Intravitreal plungerless injector device (IPLID) for anterior chamber paracentesis: a novel approach to aqueous humor sampling

delete2026-03-01
delete0
PRE
AI
Y
Yepez, Juan B.
M
Murati, Felipe A.
K
Kozak, Igor
A
Arevalo, J. Fernando *
DOI:10.1007/s00417-026-07218-zdelete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Purpose To evaluate the feasibility and preliminary safety of a plungerless intravitreal injector device (IPLID) adapted for aqueous humor aspiration during anterior chamber paracentesis. Methods In this proof-of-concept pilot study, ten consecutive eyes undergoing diagnostic anterior chamber paracentesis with the IPLID were prospectively enrolled and compared with a retrospective cohort of ten eyes that underwent conventional syringe-based aspiration. Procedures were performed under slit-lamp visualization. Primary outcomes included feasibility and procedure duration. Secondary outcomes included aspirated volume, intraocular pressure (IOP) changes, wound integrity, patient discomfort (visual analogue scale), and surgeon-reported usability. Results All procedures were successfully completed without intraoperative complications. The device achieved consistent aqueous humor aspiration (48 +/- 5 & micro;L) compared with greater variability using conventional methods (59 +/- 17 & micro;L). No anterior chamber instability or hypotony occurred. Wounds were self-sealing in all cases, whereas two control cases required bandage contact lenses. Procedure time was shorter and patient discomfort lower with the IPLID (p < 0.01). No adverse events were observed during one-week follow-up. Conclusions The plungerless intravitreal injector device appears to be a feasible and safe alternative for anterior chamber paracentesis, enabling controlled and reproducible aqueous humor sampling with improved procedural consistency and patient comfort. Larger prospective studies are warranted to confirm these findings and assess long-term safety.
Keywords:
Anterior chamber paracentesis
Aqueous humor sampling
Plungerless injector
Intravitreal injection device
Ophthalmic surgical devices
Aqueous humor aspirationx
Aqueous humor aspiration
Minimally invasive ophthalmic procedures
Diagnostic ophthalmology

Journal

G
Graefes Archive for Clinical and Experimental Ophthalmology
IF:
2.3
Papers:
276
Citations:
1.2W

Organization

U
university of arizona
Scholars:
3.8K
Papers: 1.8K
Citations: 0
J
Johns Hopkins Medicine
Scholars:
1.7W
Papers: 1.3W
Citations: 5.0W
J
johns hopkins university
Scholars:
8.9K
Papers: 3.4K
Citations: 1
U
universidad de chile
Scholars:
2.0W
Papers: 1.4W
Citations: 18
Cited Papers

Cited Papers

Citing Papers

Citing Papers