1
Return

Investigating the structural responses of medial collagen and elastin to traction to elucidate mechanical property differences in porcine aorta and pulmonary artery

delete2026-05-10
delete0
delete
OA
AI
K
Kenzo Yamamoto *
H
Hayato Laurence Mizuno
K
Kazuaki Hara
T
Tatsuya Yamakawa
H
Hidetaka Hontani
I
Ichiro Sakuma
E
Etsuko Kobayashi *
DOI:10.1016/j.actbio.2026.05.016delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Along with the rising interest in regenerative medicine and tissue engineering comes the necessity to gain a deeper understanding of the underlying nature behind the mechanical responses of various soft tissues. This study investigates the differences in mechanical responses of the aorta and pulmonary artery, both of which share similar trilayered structures, by examining how their microstructural architectures influence their response to traction forces. As such, two-photon microscopy was used to visualize elastin and collagen fibers, via two-photon excited autofluorescence and second-harmonic generation respectively, during a mode I tensile fracture test on trouser-shaped specimens harvested from the aorta and pulmonary artery. The tensile tests revealed that while the aorta exhibited significantly higher low-strain elasticity compared to the pulmonary artery (aorta: 184.9 ± 37.4 kPa, pulmonary artery: 25.9 ± 6.0 kPa), both tissues required comparable forces for fracture propagation under mode I fracture (aorta: 7.6 ± 3.4 N, pulmonary artery: 6.3 ± 4.5 N). In this study, the possible reasons behind these mechanical disparities are discussed based on the microscopic images depicting the specimen’s histologic structural deformation throughout the tensile test. Elastic responses from the aorta and pulmonary artery were discussed using static images of the elastin and collagen networks taken at a fixed interval during the tensile test. Moreover, this study presents the first successful acquisition of a microscopic video capturing the microstructural failure dynamics during arterial fracture, which served as a basis for discussion on the fracture properties of the aorta and pulmonary artery under mode I loading. These findings offer insights into fracture propagation mechanisms in arteries and underscore the importance of microstructural analysis for elucidating soft tissue biomechanics.
Keywords:
aorta
pulmonary artery
collagen
elastin
mechanical properties
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Acta Biomaterialia cover
Acta Biomaterialia
IF:
9.6
Papers:
1.0W
Citations:
6.5W

Organization

E
Error
Scholars:
1.9K
Papers: 731
Citations: 0
N
nagoya institute of technology
Scholars:
342
Papers: 159
Citations: 0
E
engineering
Scholars:
1.4K
Papers: 766
Citations: 0
I
Invalid
Scholars:
4.0K
Papers: 1.7K
Citations: 0
I
institute of science tokyo
Scholars:
2.6K
Papers: 1.0K
Citations: 0
C
center for research and collaboration
Scholars:
1
Papers: 1
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers