k-Space deep learning for reference-free EPI ghost correction

delete2019-07-18
delete21
delete
OA
AI
J
Ju Young Lee
Y
Yoseob Han
J
Jae‐Kyun Ryu
J
Jang‐Yeon Park
J
Jong Chul Ye *
DOI:10.1002/mrm.27896delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose Nyquist ghost artifacts in echo planar imaging (EPI) are originated from phase mismatch between the even and odd echoes. However, conventional correction methods using reference scans often produce erroneous results especially in high-field MRI due to the nonlinear and time-varying local magnetic field changes. Recently, it was shown that the problem of ghost correction can be reformulated as k-space interpolation problem that can be solved using structured low-rank Hankel matrix approaches. Another recent work showed that data driven Hankel matrix decomposition can be reformulated to exhibit similar structures as deep convolutional neural network. By synergistically combining these findings, we propose a k-space deep learning approach that immediately corrects the phase mismatch without a reference scan in both accelerated and non-accelerated EPI acquisitions. Theory and Methods To take advantage of the even and odd-phase directional redundancy, the k-space data are divided into 2 channels configured with even and odd phase encodings. The redundancies between coils are also exploited by stacking the multi-coil k-space data into additional input channels. Then, our k-space ghost correction network is trained to learn the interpolation kernel to estimate the missing virtual k-space data. For the accelerated EPI data, the same neural network is trained to directly estimate the interpolation kernels for missing k-space data from both ghost and subsampling. Results Reconstruction results using 3T and 7T in vivo data showed that the proposed method outperformed the image quality compared to the existing methods, and the computing time is much faster. Conclusions The proposed k-space deep learning for EPI ghost correction is highly robust and fast, and can be combined with acceleration, so that it can be used as a promising correction tool for high-field MRI without changing the current acquisition protocol.
Keywords:
deep convolutional framelet
deep learning k-space learning
EPI
Nyquist ghost artifact
MRI
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

I
institute for basic science - korea (ibs)
Scholars:
6.7K
Papers: 5.2K
Citations: 13
Cited Papers

Cited Papers

PEC-GRAPPA reconstruction of simultaneous multislice EPI with slice-dependent 2D Nyquist ghost correction
err2018-10-12
err11
PREAI
errLiu, Yilong; Lyu, Mengye; Barth, Markus; Yi, Zheyuan; Leong, Alex T. L.; Chen, Fei; Feng, Yanqiu; Wu, Ed X.
errShare
errSave
A Simple Synthesis of β-Amino Sulfides
err1997-08-01
err0
PREAI
errHiroyuki Ishibashi; Masayuki Uegaki; Manami Sakai
errShare
errSave
errShare
errSave
errShare
errSave
researcher View more