arrow
Return

Membrane evaporators

delete2002-05-31
delete25
PRE
AI
N
Nii, S
J
Jebson, RS
C
Cussler, EL
DOI:10.1016/S0376-7388(01)00725-6delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
We have built and tested a flat-sheet membrane evaporator for removing water from dilute feed streams like milk and orange juice. The energy for the water's evaporation comes from steam channels next to the feed channels, so that the operation differs sharply from other forms of membrane distillation. The membrane evaporator retains flavors effectively. Because it has an overall vapor phase mass transfer coefficient of about 1 cm/s, it is only 68% efficient: only about 0.68 kg water is evaporated per kg steam condensed. This efficiency should be over 95% for a membrane which is 10 times more permeable. (C) 2002 Elsevier Science B.V. All rights reserved.
Keywords:
pervaporation
liquid permeability and separations
membrane distillation
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Journal of Membrane Science cover
Journal of Membrane Science
IF:
9
Papers:
2.1W
Citations:
9.4W

Organization

No organization information available
Cited Papers

Cited Papers

No cited papers available