In this article, a novel resonator design of a planner microwave sensor for biosensing applications is proposed. The sensor consists of double asymmetric split ring resonators (SRRs) enclosed by a feeding loop. This design leads to high electric field confinement at the sensing area, yet low loss that leads to a high level of sensitivity. The sensor was designed to address various tradeoffs, such as physical dimensions versus a suitable frequency for acceptable penetration depth. The numerical and experimental results are in very good agreement with each other. The resonance frequency shift that appears in the transmission amplitude coefficient as a result of coating a dielectric material on the sensor was the main metric to evaluate the sensitivity. This shift was found to be well-correlated to the change of the dielectric constant of the coated material. The results demonstrate the applicability of the sensor to detect small changes in the dielectric constant. The sensitivity of the biosensor is presented as the coated material thickness varies. Most importantly, this sensor can be utilized to detect a very small amount of analyte with a thickness of one-thousandths of the operation wavelength. The response shows that the frequency shift follows an exponential model as the thickness increases. The design possesses a very high sensitivity of 4.3x10(5) nm/RIU/mm(3). Therefore, the proposed design of the biosensor would ultimately be a great choice to be incorporated with such detection systems for biological substances.
Keywords:
Biosensing
dielectric constant
microwave
resonator

Journal

IEEE Sensors Journal cover
IEEE Sensors Journal
IF:
4.5
Papers:
2.2W
Citations:
7.3W

Organization

I
Imam Abdulrahman Bin Faisal University
Scholars:
6.3K
Papers: 4.5K
Citations: 5.4K
Cited Papers

Cited Papers

errShare
errSave
Separating value from selection frequency in rapid reaching biases to visual targets
err2014-12-06
err0
PREAI
errCraig S. Chapman; Jason P. Gallivan; James T. Enns
errShare
errSave
Evaluation of a quality improvement initiative to increase rates of advance directive conversation documentation in primary care
err2021-01-01
err0
PREAI
errVictoria R. Marino; Kathryn Hyer; LaChiana Hamilton; Anne Maynard Wenders; Ross Andel
errShare
errSave
Cybernetic Revolutionaries
err
IF0
err2011-10-28
err0
PREAI
errEden Medina
errShare
errSave
researcher View more