arrow
Return

MR-Based Conductivity Imaging Using Multiple Receiver Coils

delete2015-09-16
delete45
delete
OA
AI
J
Joonsung Lee
J
Jaewook Shin
D
Dong‐Hyun Kim *
DOI:10.1002/mrm.25891delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose: To propose a signal combination method for MR-based tissue conductivity mapping using a standard clinical scanner with multiple receiver coils. Methods: The theory of the proposed method is presented with two practical approaches, a coil-specific approach and a subject-specific approach. Conductivity maps were reconstructed using the transceive phase of the combined signal. The sensitivities of the coefficients used for signal combination were analyzed and the method was compared with other signal combination methods. For validation, multiple receiver brain coils and multiple receiver breast coils were used in phantom, in vivo brain, and in vivo breast studies. Results: The variation among the conductivity estimates was <15% as determined by the coefficient sensitivity tests. Compared with other signal combination methods, the proposed method yielded fewer artifacts in the conductivity estimates. Conclusion: MR-based tissue conductivity mapping is feasible when using a standard clinical MR scanner with multiple receiver coils. The proposed method reduces systematic errors in phase-based conductivity mapping that can occur due to the inhomogeneous magnitude of the combined receive profile. (C) 2015 Wiley Periodicals, Inc.
Keywords:
conductivity
electrical property imaging
MREPT
phase-based EPT
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

I
institute for basic science - korea (ibs)
Scholars:
6.7K
Papers: 5.2K
Citations: 13
S
sungkyunkwan university (skku)
Scholars:
3.7W
Papers: 3.6W
Citations: 49
Cited Papers

Cited Papers

Ultra fast electromagnetic field computations for RF multi-transmit techniques in high field MRI
err2009-01-30
err35
PREAI
errvan den Bergen, Bob; Stolk, Christiaan C.; van den Berg, Jan Bouwe; Lagendijk, Jan J. W.; Van den Berg, Cornelis A. T.
errShare
errSave
Transmit SENSE
err2002-12-31
err766
errOAAI
errKatscher, U; Börnert, P; Leussler, C; van den Brink, JS
errShare
errSave
errShare
errSave
MRI with Zero Echo Time: Hard versus Sweep Pulse Excitation
err2011-03-04
err182
errOAAI
errWeiger, Markus; Pruessmann, Klaas P.; Hennel, Franciszek
errShare
errSave
researcher View more