PURPOSE . The purpose of this study was to provide a large, multi-center normative dataset for the Macular Integrity Assessment (MAIA) microperimeter and compare the goodness-of-fit and prediction interval calibration-error for a panel of hill-of-vision models. METHODS . Microperimetry examinations of healthy eyes from five independent study groups and one previously available dataset were included (1137 tests from 531 eyes of 432 participants [223 women and 209 men]). Linear mixed models (LMMs) were fitted to the data to obtain interpretable hill-of-vision models. A panel of regression models to predict normative data was compared using cross-validation with site-wise splits. The mean absolute error (MAE) and miscalibration area (area between the calibration curve and the ideal diagonal) were evaluated as the performance measures. RESULTS . Based on the parameters participant age, eccentricity from the fovea, overlap with the central fixation target, and eccentricity along the four principal meridians, a Bayesian mixed model had the lowest MAE (2.13 decibel [dB]; 95% confidence interval [CI] = 1.9-2.36 dB) and miscalibration area (0.13; 95% CI = 0.07-0.19). However, a parsimonious linear model provided a comparable MAE (2.17 dB; 95% CI = 1.93-2.4 dB) and a similar miscalibration area (0.14; 95% CI = 0.08-0.2). CONCLUSIONS . Normal variations in visual sensitivity on mesopic microperimetry can be effectively explained by a linear model that includes age and eccentricity. The dataset and a code vignette are provided for estimating normative values across a large range of retinal locations, applicable to customized testing patterns.
Keywords:
microperimetry
static perimetry
visual psychophisics
mesopic light sensitiv- ity
fundus-controlled perimetry
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

I
Investigative Ophthalmology and Visual Science
IF:
4.7
Papers:
1.7W
Citations:
5.5W

Organization

U
University of Western Australia
Scholars:
2.9W
Papers: 3.0W
Citations: 46
U
University of Basel
Scholars:
3.1W
Papers: 2.4W
Citations: 38
U
university of bonn
Scholars:
3.3W
Papers: 2.6W
Citations: 29
A
Anglia Ruskin University
Scholars:
2.6K
Papers: 2.5K
Citations: 3.3K
U
university of oxford
Scholars:
9.7W
Papers: 8.6W
Citations: 137
M
Moorfields Eye Hospital NHS Foundation Trust
Scholars:
1.3K
Papers: 1.0K
Citations: 1.8K
researcher View more organizations