arrow
Return

Multidimensional Clutter Filter Optimization for Ultrasonic Perfusion Imaging

delete2018-11-01
delete35
PRE
AI
M
MinWoo Kim
Y
Yang Zhu
J
Jamila Hedhli
L
Lawrence W. Dobrucki
M
Michael F. Insana *
DOI:10.1109/TUFFC.2018.2868441delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Combinations of novel pulse-echo acquisitions and clutter filtering techniques can improve the sensitivity and the specificity of power Doppler (PD) images, thus reducing the need for exogenous contrast enhancement. We acquire echoes following bursts of Doppler pulse transmissions sparsely applied in regular patterns over long durations. The goal is to increase the sensitivity of the acquisition to slow disorganized patterns of motion from the peripheral blood perfusion. To counter a concomitant increase in clutter signal power, we arrange the temporal echo acquisitions into two data-array axes, combine them with a spatial axis for the tissue region of interest, and apply 3-D singular-value decomposition (SVD) clutter filtering. Successful separation of blood echoes from other echo signal sources requires that we partition the 3-D SVD core tensor. Unfortunately, the clutter and blood subspaces do not completely uncouple in all situations, so we developed a statistical classifier that identifies the core tensor subspace dominated by tissue clutter power. This paper describes an approach to subspace partitioning as required for optimizing PD imaging of peripheral perfusion. The technique is validated using echo simulation, flow-phantom data, and in vivo data from a murine melanoma model. We find that for narrow eigen-bandwidth clutter signals, we can routinely map phantom flows and tumor perfusion signals at speeds less than 3 mL/min. The proposed method is well suited to peripheral perfusion imaging applications.
Keywords:
Higher order singular-value decomposition (HOSVD)
peripheral perfusion imaging
source separation
subspace partitioning
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control cover
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
IF:
3.7
Papers:
6.7K
Citations:
1.4W

Organization

U
University of Illinois Urbana-Champaign
Scholars:
2.4W
Papers: 2.0W
Citations: 35
University of Illinois System cover
University of Illinois System
Scholars:
6.8W
Papers: 6.2W
Citations: 644