Multimodal PET–MR segmentation for glioblastoma: complementarity for treatment planning and recurrence definition

delete2026-07-20
delete0
delete
OA
AI
A
Alejandro Mora-Rubio *
D
Dejan Kuhn
C
Carolina Bravo-Vergara
T
Tobias Fechter
M
Melissa Mauer
M
María Beser‐Robles
I
Irene Marín Radoszynski
R
Rocío Catalán Flores
J
Johannes Fostitsch
P
Pablo García Verdú
M
Michael Mix
D
Dimos Baltas
L
Luis Martí‐Bonmatí
A
Anca-Ligia Grosu
I
Ilinca Popp
M
M. Carles
DOI:10.1186/s40644-026-01086-wdelete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
In patients with Glioblastoma (GBM), Magnetic Resonance (MR) is used for tumour diagnosis and treatment planning. Positron Emission Tomography (PET) with O-(2)-18 F-Fluoroethyl-L-Tyrosine (FET) has been recommended to distinguish local recurrence from radiogenic alterations. However, clinical practice remains hindered by the time and expertise required for tumour and organs-at-risk (OARs) segmentation and the limited evidence of the added value of PET and its restricted availability across clinical centres. This study presents automatic segmentation models and a comprehensive evaluation of PET/MR complementary biological information for recurrent disease definition. The nnU-Net was employed for segmentation using manually defined contours on 1,610 patients from 33 institutions. Model performance was evaluated by Dice-Sørensen-Coefficient (DSC). PET/MR recurrence complementarity was evaluated in 185 patients by Wilcoxon-Signed-Rank test (WSRT), DSC and radiomic features (RF). In RF analysis, MR-Enhancing subregions were classified as MR∩PET or MR-Only, based on overlap with PET. For MR-RF showing significant MR∩PET/MR-Only differences (WSRT), discrimination was further assessed by classifying RF for 3 × 3 × 3-voxel subregions within MR-Enhancing in two volumes (greater/less than the RF cohort median) and evaluating Positive-Predictive-Value and Sensitivity with MR∩PET/MR-Only. Models’ performance in the test set resulted in DSC(MR-Enhancing) = 0.76 ± 0.24, DSC(MR-Edema) = 0.69 ± 0.23, DSC(PET-Uptake) = 0.71 ± 0.20, DSC(Planning-Target-Volume) = 0.93 ± 0.05, DSC(OARs) = 0.70 ± 0.13. Manual MR and FET-PET based GBM recurrence delineations differed significantly in size (p = 0.0497) and location (DSC = 0.45 ± 0.20). From the 37 MR-RF showing significant differences between MR∩PET and MR-Only (p < 0.05), none of the MR-Enhancing based RF-maps allowed spatial identification of PET findings (positive-predictive-value and sensitivity < 0.6). The resulted segmentation models could facilitate PET/MR integration in GBM treatment. PET/MR comparison supports the complementarity of FET-PET.
Keywords:
Glioblastoma
Convolutional neural network
Segmentation
Radiomics
Radiation oncology

Journal

Cancer Imaging cover
Cancer Imaging
IF:
3.5
Papers:
1.3K
Citations:
3.5K

Organization

D
department of radiology
Scholars:
3.0K
Papers: 963
Citations: 0
H
health research institute la fe
Scholars:
109
Papers: 30
Citations: 0
F
faculty of medicine
Scholars:
6.0K
Papers: 2.1K
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers