arrow
Return

Multiplexed SOI BioFETs

delete2011-10-01
delete45
delete
OA
AI
A
Aleksandar Vacic *
J
Jason M. Criscione
E
Eric Stern
N
Nitin K. Rajan
T
Tarek M. Fahmy
M
Mark A. Reed
DOI:10.1016/j.bios.2011.07.025delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Nanoscale Field Effect Transistors have emerged as a promising technology for ultrasensitive, unlabeled diagnostic applications. However, their use as quantitative sensors has been problematic because of the need for individual sensor calibration. In this work we demonstrate an internal calibration scheme for multiplexed nanoribbon field effect sensors by utilizing the initial current rates rather than end point detection. A linear response is observed consistent with initial binding kinetics. Moreover, we are able to show that top-down fabrication techniques yield reproducible device results with minimal fluctuations, enabling internal calibration. (C) 2011 Elsevier B.V. All rights reserved.
Keywords:
Nanoscale
Label-free
BioFET
Calibration
Multiplexed

Journal

Biosensors and Bioelectronics cover
Biosensors and Bioelectronics
IF:
10.5
Papers:
1.8W
Citations:
7.7W

Organization

Y
Yale University
Scholars:
6.5W
Papers: 6.0W
Citations: 10.0W
Cited Papers

Cited Papers

The Bioinorganic Chemistry of Mammalian Metallothioneins
err2021-10-15
err0
PREAI
errArtur Krężel; Wolfgang Maret
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Quantitative real-time measurements of DNA hybridization with alkylated nonoxidized silicon nanowires in electrolyte solution
err2006-12-01
err509
errOAAI
errBunimovich, Yuri L.; Shin, Young Shik; Yeo, Woon-Seok; Amori, Michael; Kwong, Gabriel; Heath, James R.
errShare
errSave
A Nanoelectronic Enzyme-Linked Immunosorbent Assay for Detection of Proteins in Physiological Solutions
errSMALL
IF12.1
err2010-01-14
err60
errOAAI
errStern, Eric; Vacic, Aleksandar; Li, Chao; Ishikawa, Fumiaki N.; Zhou, Chongwu; Reed, Mark A.; Fahmy, Tarek M.
errShare
errSave
Bioassay of prostate-specific antigen (PSA) using microcantilevers
err2001-09-01
err1.1K
PREAI
errWu, GH; Datar, RH; Hansen, KM; Thundat, T; Cote, RJ; Majumdar, A
errShare
errSave
A Calibration Method for Nanowire Biosensors to Suppress Device-to-Device Variation
err2009-11-18
err140
errOAAI
errIshikawa, Fumiaki N.; Curreli, Marco; Chang, Hsiao-Kang; Chen, Po-Chiang; Zhang, Rui; Cote, Richard J.; Thompson, Mark E.; Zhou, Chongwu
errShare
errSave
researcher View more