arrow
Return

New design method for large involute artifacts

delete2022-07-01
delete5
PRE
AI
H
Hongfang Chen
C
Chaowei Liang
Z
Zhaoyao Shi *
H
Hao Xu
T
Tianshui Wei
胡林 cover
胡林 (Lin Hu)
H
Huakun Xie
DOI:10.1016/j.precisioneng.2022.03.007delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Owing to the difficulty in processing and measuring large involute artifacts, the value transfer of large gears remains a challenge. In this study, by replacing the involute tooth profile with an arc, a new double-axis arc-shaped large-size involute artifact was constructed, and a design method for the artifact was proposed. In the newly designed large-size involute artifact, the diameter of the reference block was 181.7744 mm, and the distance from the center of the reference block to the axis of the centering axis was 362.1212 mm. The artifact was tested using the Klingelnberg Gear Measuring Center P100. Three performance indicators f(VB), f(FK) and f(NC) are proposed to evaluate the gear measurement instrument. The experimental results demonstrated that the developed double-axis arc-shaped large-size involute artifact satisfied the high-precision requirements for the processing and inspection of artifacts. The paper provides theoretical support for establishing the value transfer and traceability system and the gear involute extension standard.
Keywords:
Involute artifact
Gear measuring instrument
Gear measurement
Large gear
Value transfer

Journal

P
Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology
IF:
3.7
Papers:
3.3K
Citations:
8.3K

Organization

B
Beijing University of Technology
Scholars:
2.8W
Papers: 2.1W
Citations: 2.7W
Cited Papers

Cited Papers

errShare
errSave
Improvement of Intensive In-Seam Gas Drainage Technology at Kirova Mine in Kuznetsk Coal Basin
err2022-01-30
err0
errOAAI
errSergey Slastunov; Konstantin Kolikov; Andrian Batugin; Anatoly Sadov; Adam Khautiev
errShare
errSave
Plate 355. Cocos nucifera
err2003-12-23
err0
PREAI
errJohn Dransfield; David Cooke
errShare
errSave
Self-Calibration Method for a Ball Plate Artefact on a CMM
err2016-01-01
err18
PREAI
errGuenther, Anke; Stoebener, Dirk; Goch, Gert
errShare
errSave
Influence and compensation of CMM geometric errors on 3D gear measurements
err2020-02-01
err37
PREAI
errLin, Hu; Keller, Frank; Stein, Martin
errShare
errSave
Advances in Large-Scale Metrology - Review and future trends
err2016-01-01
err210
PREAI
errSchmitt, R. H.; Peterek, M.; Morse, E.; Knapp, W.; Galetto, M.; Haertig, F.; Goch, G.; Hughes, B.; Forbes, A.; Estler, W. T.
errShare
errSave
Evaluation of instruments for helix measurement using wedge artifact
err2010-10-01
err15
PREAI
errKondo, Yohan; Kondo, Koshi; Osawa, Sonko; Sato, Osamu; Komori, Masaharu; Takeoka, Fumi; Kubo, Aizo; Okamoto, Kazuhiko; Sasajima, Kazuyuki
errShare
errSave
researcher View more