arrow
Return

Non-Invasive Heart Failure Evaluation Using Machine Learning Algorithms

delete2024-03-31
delete4
delete
OA
AI
V
Victor Adeyi Odeh
Y
Yifan Chen
X
Xiaorong Ding *
DOI:10.3390/s24072248delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Heart failure is a prevalent cardiovascular condition with significant health implications, necessitating effective diagnostic strategies for timely intervention. This study explores the potential of continuous monitoring of non-invasive signals, specifically integrating photoplethysmogram (PPG) and electrocardiogram (ECG), for enhancing early detection and diagnosis of heart failure. Leveraging a dataset from the MIMIC-III database, encompassing 682 heart failure patients and 954 controls, our approach focuses on continuous, non-invasive monitoring. Key features, including the QRS interval, RR interval, augmentation index, heart rate, systolic pressure, diastolic pressure, and peak-to-peak amplitude, were carefully selected for their clinical relevance and ability to capture cardiovascular dynamics. This feature selection not only highlighted important physiological indicators but also helped reduce computational complexity and the risk of overfitting in machine learning models. The use of these features in training machine learning algorithms led to a model with impressive accuracy (98%), sensitivity (97.60%), specificity (96.90%), and precision (97.20%). Our integrated approach, combining PPG and ECG signals, demonstrates superior performance compared to single-signal strategies, emphasizing its potential in early and precise heart failure diagnosis. The study also highlights the importance of continuous monitoring with wearable technology, suggesting a significant stride forward in non-invasive cardiovascular health assessment. The proposed approach holds promise for implementation in hardware systems to enable continuous monitoring, aiding in early detection and prevention of critical health conditions.
Keywords:
heart failure
photoplethysmogram
echocardiogram
machine learning
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Sensors cover
Sensors
IF:
3.5
Papers:
7.2W
Citations:
20.9W

Organization

No organization information available
Cited Papers

Cited Papers

Hypertension Assessment via ECG and PPG Signals: An Evaluation Using MIMIC Database
err2018-09-10
err95
errOAAI
errLiang, Yongbo; Chen, Zhencheng; Ward, Rabab; Elgendi, Mohamed
errShare
errSave
Epidemiology of heart failure
err2020-06-01
err1.2K
errOAAI
errGroenewegen, Amy; Rutten, Frans H.; Mosterd, Arend; Hoes, Arno W.
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Anomalous Switching Curves in a dc SQUID Phase Qubit
err2011-06-01
err0
PREAI
errH. Kwon; A. J. Przybysz; B. K. Cooper; H. Paik; K. D. Osborn; B. S. Palmer; R. Budoyo; J. R. Anderson; C. J. Lobb; F. C. Wellstood
errShare
errSave
Wearable technology: using Google Glass as a teaching tool
err2015-05-12
err0
errOAAI
errHui Min Knight; Parag Ravindra Gajendragadkar; Awais Bokhari
errShare
errSave
Effect of potentially modifiable risk factors associated with myocardial infarction in 52 countries (the INTERHEART study): case-control study
errLANCET
IF88.5
err2004-09-01
err8.2K
errOAAI
errYusuf, S; Hawken, S; Ounpuu, S; Dans, T; Avezum, A; Lanas, F; McQueen, M; Budaj, A; Pais, P; Varigos, J; Liu, LS
errShare
errSave
researcher View more