arrow
Return

Operator learning curve with a novel dual-energy lattice-tip ablation system

delete2026-01-01
delete2
PRE
AI
E
Erich L. Kiehl *
S
Stavros Mountantonakis
M
Moussa Mansour
D
Devi G. Nair
D
Dinesh C Sharma
T
Tyler L. Taigen
P
Petr Neužil
J
Josef Kautzner
J
José Osorio
A
Andrea Natale
J
John D. Hummel
A
Anish K. Amin
U
Usman R. Siddiqui
A
Alan Bulava
S
Shephal K. Doshi
C
Chinmay Patel
R
Roderick Tung
D
Doron Harlev
P
Paul Hultz
S
S. P. Rosen
K
Kelly A. van Bragt
K
Khaldoun G. Tarakji
V
Vivek Y. Reddy
E
Elad Anter
DOI:10.1016/j.hrthm.2025.02.006delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BACKGROUND The SPHERE Per-AF trial demonstrated noninferiority for a primary composite effectiveness endpoint in patients with persistent atrial fibrillation (AF) treated with a 9-mm, lattice-tip, pulsed field (PF)/radiofrequency (RF) system (74%) vs conventional contact force-sensing RF (65%). Although operators were highly experienced with the control, the vast majority was new to the investigational system. OBJECTIVE The aim of this study was to assess the learning curve using this novel system. METHODS Patients were grouped based on the sequential procedures performed per operator. Operators who performed <2 investigational procedures were excluded. The composite effectiveness endpoint was freedom from acute procedural failure, repeat ablation at any time, recurrence of arrhythmia, drug initiation/escalation, or cardioversion each at 1 year excluding a 3-month blanking period. Efficiency endpoints included skin-to-skin procedure time. RESULTS The total cohort included 443 patients (235 investigational [31 roll-in], 208 control). Primary effectiveness in the investigational cohort improved significantly with increased procedural order. Efficacy was 65% (74 of 114) for the first 5 patients per operator, 75% (33 of 44) for patients 6 to 10, and 80% (60 of 75) for patients >10. Kaplan-Meier effectiveness estimates at 1-year follow-up were significantly higher in the investigational cohort after 10 procedures performed, compared with control (80% vs 65%, P < .05). With the investigational system, total procedure time was reduced by 25 minutes (100 vs 125) within the first 5 procedures performed (P < .001). CONCLUSION AF ablation with a novel dual-energy, lattice-tip ablation system resulted in greater clinical efficacy compared with conventional RF after a rapid operator learning curve, with superior procedural efficiency noted from the initial procedures onward.
Keywords:
Affera
Atrial fibrillation
Catheter ablation
Lattice-tip catheter
Learning curve
Pulsed field ablation
Sphere-9

Journal

Heart Rhythm cover
Heart Rhythm
IF:
5.7
Papers:
9.6K
Citations:
1.6W

Organization

I
institute for clinical & experimental medicine (ikem)
Scholars:
1.8K
Papers: 1.3K
Citations: 1
M
Massachusetts General Hospital
Scholars:
3.4W
Papers: 2.6W
Citations: 8.6W
U
University System of Ohio
Scholars:
15.2W
Papers: 12.9W
Citations: 200
M
maimonides medical center
Scholars:
81
Papers: 39
Citations: 0
S
sentara healthcare
Scholars:
331
Papers: 284
Citations: 1
H
harvard university
Scholars:
2.5K
Papers: 1.0K
Citations: 1
H
harvard university medical affiliates
Scholars:
5.7W
Papers: 4.5W
Citations: 36
H
hospital ceske budejovice
Scholars:
158
Papers: 127
Citations: 0
O
ohio state university
Scholars:
1.4K
Papers: 734
Citations: 2
U
university of south bohemia ceske budejovice
Scholars:
3.7K
Papers: 2.7K
Citations: 9
U
University of Arizona
Scholars:
3.6W
Papers: 3.2W
Citations: 980
M
Medtronic
Scholars:
1.6K
Papers: 1.1K
Citations: 10
T
tel aviv university
Scholars:
4.9K
Papers: 1.9K
Citations: 1
N
Na Homolce Hospital
Scholars:
542
Papers: 466
Citations: 599
researcher View more organizations