arrow
Return

Optimal Linear Combinations of Array Elements for B1 Mapping

delete2009-08-05
delete21
delete
OA
AI
S
Shaihan Malik
D
David J. Larkman
J
Joseph V. Hajnal *
DOI:10.1002/mrm.22068delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Accuracy of Ell mapping for array coils can be improved by mapping the fields produced by driving linear combinations of the array elements, chosen to produce a more uniform distribution of B, amplitude. Quality of the resulting single element B, maps is influenced by the transformation used both via the uniformity of the resulting linear combination fields and by the degree to which these linear combinations differ from one another. In this work we investigate the effect of using different transformations on the quality of B-1 maps by simulating the B, mapping process for two different techniques, using real data from a 3T 8-channel body transmit system. Different transformations are generated using a single complex parameter. It is demonstrated that the optimal transformation within this framework is different for different imaging targets (pelvis and brain of healthy volunteers, and water and oil phantoms). For the same target (pelvis) the optimum condition, however, is similar for a number of subjects, suggesting that optimal configurations to be used for calibrating coils in specific anatomical contexts can be determined in advance. Potential gains may be translated into significant reductions in scan time for equivalent signal-to-noise ratio coil maps. Magn Reson Med 6 902-909, 2009. (C) 2009 Wiley-Liss, Inc.
Keywords:
linear combinations
B1 mapping
parallel transmission MRI
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

I
Imperial College London
Scholars:
8.3W
Papers: 7.3W
Citations: 11.1W
Cited Papers

Cited Papers

Eight-channel transmit/receive body MRI coil at 3T
err2007-07-24
err121
errOAAI
errVernickel, P.; Roeschmann, P.; Findeklee, C.; Luedeke, K.-M.; Leussler, Ch.; Overwag, J.; Katscher, U.; Graesslin, I.; Schuenemann, K.
errShare
errSave
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
err2005-11-03
err451
PREAI
errVan De Moortele, PF; Akgun, C; Adriany, G; Moeller, S; Ritter, J; Collins, CM; Smith, MB; Vaughan, JT; Ugurbil, K
errShare
errSave