Optimization for ice-storage air-conditioning system using particle swarm algorithm

delete2009-09-01
delete129
PRE
AI
W
Wen‐Shing Lee *
Y
Yi –Ting Chen
T
Ting‐Hau Wu
DOI:10.1016/j.apenergy.2008.12.025delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Ice-storage air-conditioning system, while known for its advantage of shifting power consumption at peak hours during the day to the nighttime, can increase both energy consumption and CO2 emission. The study adopts particle swarm algorithm to facilitate optimization of ice-storage air-conditioning systems and to develop optimal operating strategies, using minimal life cycle cost as the objective function. Increase in power consumption and CO2 emission triggered by the use of ice-storage air-conditioning system is also examined and analyzed. Case study is based on a typical air-conditioning system in an office building. Results indicate that, with proper parameters, particle swarm algorithm can be effectively applied to the optimization of ice-storage air-conditioning system. in addition, optimal capacity of the ice-storage tank can be obtained. However, the volume of power consumption and CO2 emission rises with the increase in ice-storage tank capacity. Consideration of additional costs of power consumption like carbon tax can therefore lead to changes in the optimal system configuration. (C) 2009 Elsevier Ltd. All rights reserved.
Keywords:
Ice-storage air-conditioning system
Particle swarm algorithm
Optimum
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Applied Energy cover
Applied Energy
IF:
11
Papers:
2.6W
Citations:
17.8W

Organization

N
National Taipei University of Technology
Scholars:
7.1K
Papers: 7.3K
Citations: 6.8K
Cited Papers

Cited Papers

Guidelines for improved performance of ice storage systems
err2003-02-01
err84
PREAI
errHenze, GP; Krarti, M; Brandemuehl, MJ
errShare
errSave
Optimal cool storage capacity for load management
errENERGY
IF9.4
err2003-02-01
err49
PREAI
errAshok, S; Banerjee, R
errShare
errSave
Performance evaluation of district cooling plant with ice storage
errENERGY
IF9.4
err2006-11-01
err77
PREAI
errChan, Apple L. S.; Chow, Tin-Tai; Fong, Square K. F.; Lin, John Z.
errShare
errSave
Parameters of Solvent Extraction for Bitumen Recovery from Oil Sands
err2011-10-07
err0
PREAI
errLin He; Xin Gang Li; Yong Liang Du; Guo Zhong Wu; Hong Li; Hong Sui
errShare
errSave
no more