arrow
Return

Optimization of self-reference thermometry using complex field estimation

delete2006-08-30
delete59
delete
OA
AI
K
Kagayaki Kuroda *
D
Daisuke Kokuryo
E
Etsuko Kumamoto
K
Kyohei Suzuki
Y
Yuichiro Matsuoka
B
Bilgin Keserci
DOI:10.1002/mrm.21016delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Referenceless, or self-reference, thermometry is a technique for mapping temperature differences in the region of interest (ROI) using the baseline phase estimated by extrapolating the field in the surrounding region for estimation (RFE) and subtracting the estimated baseline from the measured field. In the present work a self-reference technique based on complex field estimation using 2D polynomials comprising complex-valued coefficients was proposed and optimized. Numerical simulations with a Gaussian-profiled phase distribution demonstrated that the ROI radius had to be 2.3-2.5 times the standard deviation (SD) of the Gaussian function in order to keep the error below 8% of the peak phase change. The area ratio between the ROI and the RFE had to be larger than 2.0 to maintain the error level. Based on the simulations, and phantom and volunteer experiments, the complex-based method with independently optimized polynomial orders for the two spatial dimensions was compared with the phase-based method using the similar-order optimization strategy. The complex-based method appeared to be useful when phase unwrapping was not removed. Otherwise, the phase-based method yielded equivalent results with less polynomial orders.
Keywords:
temperature
self-reference
referenceless
proton
chemical shift
resonance frequency
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

No organization information available
Cited Papers

Cited Papers

A phase field model of capillarity
err1995-04-01
err0
PREAI
errLeonid K. Antanovskii
errShare
errSave
Stability of real-time MR temperature mapping in healthy and diseased human liver
err2004-03-29
err84
errOAAI
errWeidensteiner, C; Kerioui, N; Quesson, B; de Senneville, BD; Trillaud, H; Moonen, CTW
errShare
errSave
Referenceless PRF shift thermometry
err2004-05-24
err274
errOAAI
errRieke, V; Vigen, KK; Sommer, G; Daniel, BL; Pauly, JM; Butts, K
errShare
errSave
Possible role for interleukins as biomarkers for mortality and recurrence in oral cancer
err2018-01-18
err0
errOAAI
errPaolo G. Arduino; Elisa Menegatti; Nazario Cappello; Eugenio Martina; Nicolò Gardino; Carlotta Tanteri; Franco Cavallo; Crispian Scully; Roberto Broccoletti
errShare
errSave
Gas and Bed Axial Composition in a Bubbling Fluidized Bed Gasifier: Results with Miscanthus and Olivine
err2016-09-21
err0
PREAI
errGeorge Lardier; Judit Kaknics; Anthony Dufour; Rudy Michel; Benjamin Cluet; Olivier Authier; Jacques Poirier; Guillain Mauviel
errShare
errSave
errShare
errSave
Infinite-Momentum Helicity States
err1972-04-15
err0
PREAI
errDavison E. Soper
errShare
errSave
researcher View more