arrow
Return

Optimization of tablet processing as a reference material for microplastic detection methods

delete2025-12-11
delete0
delete
OA
AI
M
Mara Putzu
Y
Yosri Wiesner
C
Christiane Weimann
V
Vasile‐Dan Hodoroaba
S
Soledad Muniategui‐Lorenzo
V
Verónica Fernández-Gonzáles
A
Andy M. Booth
A
Amaia Igartua
N
Nizar Benismail
L
Laureen Coïc
C
Carine Chivas‐Joly
I
Ivana Fenoglio
A
Andrea Mario Rossi
A
Andrea Mario Giovannozzi
K
Korinna Altmann *
DOI:10.1007/s00216-025-06271-7delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Reference materials (RMs) are essential and highly demanded tools for the development and validation of methods for microplastic (MP) quantification in complex matrices, to ensure comparable and harmonized approaches aligned with EU commission criteria for monitoring MPs (e.g., Drinking Water Directive and Urban Wastewater Treatment Directive). This study investigates different approaches for optimizing the production of polypropylene (PP) RMs in the form of water-soluble tablets, which were carefully evaluated for their homogeneity and stability according to ISO Guide 30, ISO 33401, and ISO 33405. PP particles (1–100 μm) were produced by cryomilling and embedded in a lactose/PEG matrix, then pressed into tablets (18 µg theoretical PP mass). The production process was optimized by varying (i) the size distribution of the matrix components and (ii) the mixer instrument. The materials obtained were characterized by thermogravimetric analysis to assess the homogeneity distribution of MPs with respect to PP mass in the individual tablets and their stability over a 4-month period. The most promising approach, with a homogenous mass of 19 μg (standard deviation of 4 μg), relative standard deviation of 19%, was further investigated for homogeneity by comparison with thermo-analytical mass determination methods, such as TED-GC/MS (thermal extraction desorption-gas chromatography/mass spectrometry) and Py-GC/MS (pyrolysis-gas chromatography-mass spectrometry), and for number-based characterization using micro-Raman spectroscopy. Material characterization was also examined using laser diffraction, scanning electron microscopy, and ATR-FTIR. Based on the results, the optimized processing protocol yields a PP RM suitable for quality control and method performance studies supporting standardization.
Keywords:
Analytical methods
Validation
Identification
Quantification
Plastic polymer
Polypropylene
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Analytical and Bioanalytical Chemistry cover
Analytical and Bioanalytical Chemistry
IF:
3.8
Papers:
1.8W
Citations:
3.5W

Organization

N
nestlé quality assurance centre (nqac)
Scholars:
2
Papers: 1
Citations: 0
L
Laboratoire National de Metrologie et d'Essais
Scholars:
6
Papers: 4
Citations: 0
U
università di torino (unito)
Scholars:
1
Papers: 1
Citations: 0
U
universidade da coruña (udc)
Scholars:
12
Papers: 5
Citations: 0
I
istituto nazionale di ricerca metrologica (inrim)
Scholars:
1.1K
Papers: 925
Citations: 0
researcher View more organizations