arrow
Return

Optimizing Multi-Microgrid Frequency via Takagi–Sugeno FOPID Controller-Based ESC Algorithm

delete2026-09-16
delete0
delete
OA
AI
S
Sarah S. Mohamed
D
Dokhyl AlQahtani
S
Sulaiman Z. Almutairi
A
Aisha F. Fareed *
E
Emad A. Mohamed
W
Wessam Arafa Hafez
DOI:10.3390/fractalfract10090645delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
The increasing replacement of synchronous generation by converter-interfaced renewable energy sources, particularly photovoltaic (PV) systems, has significantly diminished the effective inertia of interconnected power networks, making frequency regulation increasingly challenging under uncertain operating conditions. To tackle this challenge, this paper proposes an implementation-oriented Takagi–Sugeno fuzzy-weighted modified fractional-order PID (TS-FOPID) controller for load-frequency control (LFC). ESC determines the optimal controller gains and fractional orders, λ and μ , offline, whereas the online TS fuzzy mechanism blends the error-dependent outputs of preconfigured Nipid elements to realize the optimized fractional actions. This structurally transparent architecture avoids the repeated online execution of ESC. Unlike predefined time fuzzy tracking methods, the proposed controller suppresses frequency deviations in both areas and the tie-line power deviation under load and photovoltaic disturbances using the same optimized parameters. The proposed TS-FOPID controller is validated using a multi-area thermal power grid consisting of two interconnected areas and compared with TS-FOTID, TS-FOPD, and TS-FOTD controllers under five test scenarios encompassing step-load disturbances, photovoltaic integration, sequential disturbances, random load variations, and combined photovoltaic and wind disturbances. Controller performance is assessed using both time-domain specifications and quantitative error indices, including the integral absolute error (IAE) and root mean square deviation (RMSD). Across the investigated scenarios, the proposed TS-FOPID controller consistently outperforms the three TS controllers. For a 1% step-load disturbance, the settling time of the Area 1 frequency deviation is reduced to 1.70 s compared with 3.12 s for TS-FOTID, 16.00 s for TS-FOPD, and 17.76 s for TS-FOTD. In addition, the proposed controller achieves aggregate IAE reductions of up to 95.94% compared with the other TS-based fractional-order controllers across the considered operating conditions, including photovoltaic integration, multiple sequential disturbances, and random load variations. Overall, these results demonstrate faster settling, lower regulation errors, and improved disturbance rejection, supporting the robustness and potential practical applicability of the proposed controller for secondary load-frequency control in renewable-integrated interconnected power systems.
Keywords:
load frequency control
fractional-order PID controller
Takagi–Sugeno fuzzy systems
renewable-integrated power systems
interconnected power systems
escape optimization algorithm

Journal

Fractal and Fractional cover
Fractal and Fractional
IF:
3.3
Papers:
4.4K
Citations:
7.6K

Organization

No organization information available
Cited Papers

Cited Papers

errShare
errSave
Load frequency control in smart grids: A review of recent developments
err2024-01-01
err16
PREAI
errWadi, Mohammed; Shobole, Abdulfetah; Elmasry, Wisam; Kucuk, Ismail
errShare
errSave
A Review of Fractional Order Calculus Applications in Electric Vehicle Energy Storage and Management Systems
err2025-09-09
err3
errOAAI
errBorja-Jaimes, Vicente; Valdez-Martinez, Jorge Salvador; Beltran-Escobar, Miguel; Cruz-Rojas, Alan; Gil-Velasco, Alfredo; Coronel-Escamilla, Antonio
errShare
errSave
Optimum Fractional Control and Disturbance Observer Design for Frequency Regulation in Isolated Airport Microgrids
err2025-12-20
err0
PREAI
errRaslan,Amr A.; Aly,Mokhtar; Mohamed,Emad A.; Said,Sayed M.; Hafez,Wessam A.; Ahmed,Emad M.; Nasrat,Loai S.; Rodriguez,José
errShare
errSave
Takagi-Sugeno fuzzy gain controller for Vehicle-to-Grid (V2G) load frequency control
err2024-12-01
err0
errOAAI
errMarsadek, Marayati; Nagi, Farrukh; Permal, Navinesshani; Ramasamy, Agileswari A. P.; Azwin, Aidil
errShare
errSave
researcher View more