arrow
Return

Parametric methods for [18F]flortaucipir PET

delete2018-12-20
delete19
delete
OA
AI
S
Sandeep S.V. Golla *
E
Emma E. Wolters
T
Tessa Timmers
R
Rik Ossenkoppele
C
Chris W.J. van der Weijden
P
Philip Scheltens
L
Lothar A. Schwarte
M
Mark A. Mintun
M
Michael D. Devous
R
Robert C. Schuit
A
Albert D. Windhorst
A
Adriaan A. Lammertsma
M
Maqsood Yaqub
B
Bart N.M. van Berckel
R
Ronald Boellaard
DOI:10.1177/0271678X18820765delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
[F-18]Flortaucipir is a PET tau tracer used to visualize tau binding in Alzheimer's disease (AD) in vivo. The present study evaluated the performance of several methods to obtain parametric images of [F-18]flortaucipir. One hundred and thirty minutes dynamic PET scans were performed in 10 AD patients and 10 controls. Parametric images were generated using different linearization and basis function approaches. Regional binding potential (BPND) and volume of distribution (V-T) values obtained from the parametric images were compared with corresponding values derived using the reversible two-tissue compartment model (2T4k_V-B). Performance of SUVr parametric images was assessed by comparing values with distribution volume ratio (DVR) and SRTM-derived BPND estimates obtained using non-linear regression (NLR). Spectral analysis (SA) (r(2 )= 0.92; slope = 0.99) derived V-T correlated well with NLR-derived V-T. RPM (r(2 )= 0.95; slope = 0.98) derived BPND correlated well with NLR-derived DVR. Although SUVr(80-100 min) correlated well with NLR-derived DVR (r(2 )= 0.91; slope = 1.09), bias in SUVr appeared to depend on uptake time and underlying level of specific binding. In conclusion, RPM and SA provide parametric images comparable to the NLR estimates. Individual SUVr values are biased compared with DVR and this bias requires further study in a larger dataset in order to understand its consequences.
Keywords:
[F-18]flortaucipir
AV-1451
tau imaging
Alzheimer's disease
parametric imaging
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

J
Journal of Cerebral Blood Flow and Metabolism
IF:
4.5
Papers:
5.9K
Citations:
2.1W

Organization

V
Vrije Universiteit Amsterdam
Scholars:
4.2W
Papers: 3.7W
Citations: 3.7W
U
university of amsterdam
Scholars:
6.0W
Papers: 5.1W
Citations: 94
V
vu university medical center
Scholars:
6.2K
Papers: 4.8K
Citations: 5
researcher View more organizations