1
Return

Performance enhancement of PV/T systems through geometric modification of spiral–tube absorbers: a 3D CFD analysis

delete2026-06-12
delete0
delete
OA
AI
B
Bahram Jafari *
K
Khashayar Hosseinzadeh *
A
Aghil Ramezani
A
A.M. Mohammadzadeh
M
Majid Eshagh Nimvari
DOI:10.1016/j.ecmx.2026.102052delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
• A novel double‑path PV/T module with spiral cooling tubes is proposed for enhanced thermal management. • 3D CFD modeling and parametric optimization are employed, coupling geometry, flow conditions, and operating parameters. • Increasing S from 3 m to 6 m reduces surface temperature and enhances thermal efficiency up to 55.8%. • The double‑path configuration improves thermal efficiency from 6.62% to 9.14%, a 38% relative increase. • Thermal efficiency rises from 5.5% to 10.64% with Reynolds number, while electrical efficiency increases marginally (10%–10.26%).
Keywords:
PV/T module thermal management
CFD
Performance enhancement
Ternary nanofluid optimization
Spiral tube
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

E
Energy Conversion and Management: X
IF:
10.9
Papers:
902
Citations:
4