Purpose: To evaluate the performance of an edge-based registration technique in correcting for respiratory motion artifacts in magnetic resonance renographic (MRR) data and to examine the efficiency of a semiautomatic software package in processing renographic data from a cohort of clinical patients. Materials and Methods: The developed software incorporates an image-registration algorithm based on the generalized Hough transform of edge maps. It was used to estimate glomerular filtration rate (GFR), renal plasma flow (RPF), and mean transit time (MTT) from 36 patients who underwent free-breathing MRR at 3T using saturation-recovery turbo-FLASH. The processing time required for each patient was recorded. Renal parameter estimates and model-fitting residues from the software were compared to those from a previously reported technique. Interreader variability in the software was quantified by the standard deviation of parameter estimates among three readers. GFR estimates from our software were also compared to a reference standard from nuclear medicine. Results: The time taken to process one patient's data with the software averaged 1264 minutes. The applied image registration effectively reduced motion artifacts in dynamic images by providing renal tracer-retention curves with significantly smaller fitting residues (P < 0.01) than unregistered data or data registered by the previously reported technique. Interreader variability was less than 10% for all parameters. GFR estimates from the proposed method showed greater concordance with reference values (P < 0.05). Conclusion: These results suggest that the proposed software can process MRR data efficiently and accurately. Its incorporated registration technique based on the generalized Hough transform effectively reduces respiratory motion artifacts in free-breathing renographic acquisitions.
Keywords:
CONTRAST-ENHANCED MRI
HOUGH TRANSFORM
GLOMERULAR-FILTRATION
COMPUTED-TOMOGRAPHY
MAGNETIC-RESONANCE
RENAL-FUNCTION
KIDNEY
MODEL
SEGMENTATION
PERFUSION
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Journal of Magnetic Resonance Imaging cover
Journal of Magnetic Resonance Imaging
IF:
3.5
Papers:
9.9K
Citations:
2.0W

Organization

U
University of Utah
Scholars:
3.0W
Papers: 2.2W
Citations: 4.6W
U
Utah System of Higher Education
Scholars:
4.6W
Papers: 4.0W
Citations: 161