arrow
Return

Performance of Purpose-Built vs Off-Label Transcatheter Devices for Aortic Regurgitation

delete2024-07-01
delete1
PRE
AI
E
Enrico Poletti
M
Matti Adam
H
Hendrik Wienemann
A
Antonio Sisinni
K
Kush Patel
I
Ignacio J. Amat‐Santos
M
Mateusz Orzałkiewicz
F
Francesco Saia
D
Damiano Regazzoli
C
Claudia Fiorina
V
Vasileios Panoulas
C
Christina Brinkmann
A
Arturo Giordano
M
Maurizio Taramasso
F
Francesco Maisano
M
Marco Barbanti
O
Ole De Backer
N
Nicolas M. Van Mieghem
A
Azeem Latib
M
Mattia Squillace
S
Stephan Baldus
M
Martin Geyer
A
Andreas Baumbach
F
Francesco Bedogni
T
Tanja K. Rudolph
L
Luca Testa *
DOI:10.1016/j.jcin.2024.05.019delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BACKGROUND Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated purpose-built Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by signi ficantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis. (c) 2024 by the American College of Cardiology Foundation.
Keywords:
dedicated device
JenaValve Trilogy
pure native aortic regurgitation
transcatheter aortic valve replacement

Journal

JACC Cardiovascular Interventions cover
JACC Cardiovascular Interventions
IF:
11.4
Papers:
8.3K
Citations:
1.8W

Organization

U
University of Copenhagen
Scholars:
7.6W
Papers: 6.6W
Citations: 86
I
irccs azienda ospedaliero-universitaria di bologna
Scholars:
1.1W
Papers: 7.1K
Citations: 6
R
Rigshospitalet
Scholars:
1.7W
Papers: 1.3W
Citations: 2.1W
Y
Yeshiva University
Scholars:
1.7W
Papers: 1.3W
Citations: 2.7K
U
University of Cologne
Scholars:
2.9W
Papers: 2.1W
Citations: 2.4W
U
universita kore di enna
Scholars:
993
Papers: 1.1K
Citations: 0
A
Albert Einstein College of Medicine
Scholars:
1.2W
Papers: 8.6K
Citations: 2.4W
I
IRCCS Policlinico San Donato
Scholars:
3.4K
Papers: 2.3K
Citations: 1.6K
E
Erasmus University Rotterdam
Scholars:
4.6W
Papers: 4.0W
Citations: 2.4W
M
Montefiore Medical Center
Scholars:
1.9W
Papers: 1.3W
Citations: 5.8K
R
Royal Brompton Hospital
Scholars:
5.2K
Papers: 4.3K
Citations: 3.9K
U
Universidad de Valladolid
Scholars:
8.1K
Papers: 6.7K
Citations: 5.9K
E
Erasmus MC
Scholars:
2.9W
Papers: 2.5W
Citations: 3.4W
Harefield Hospital cover
Harefield Hospital
Scholars:
942
Papers: 701
Citations: 1.9K
B
barts health nhs trust
Scholars:
6.8K
Papers: 4.5K
Citations: 6
V
Vita-Salute San Raffaele University
Scholars:
2.7W
Papers: 1.6W
Citations: 1.4W
I
IRCCS Ospedale San Raffaele
Scholars:
1.4W
Papers: 1.0W
Citations: 6.0K
researcher View more organizations