arrow
Return

Periodic open and closed resonators as a biosensor using two computational methods

delete2024-05-24
delete7
delete
OA
AI
Z
Zaky A. Zaky *
A
Ahmed S. Hendy
W
Wael Badawy
A
Arafa H. Aly
DOI:10.1038/s41598-024-61987-3delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
The volatile particles and molecules in our dry exhaled breath can reveal enormous information about the health of any person, such as the person's respiratory and metabolic functioning. Beyond the carbon dioxide level is an indicator of life, it provides important health-related data like people's metabolic rate. This study considers periodic open and closed resonators for measuring carbon dioxide concentration in dry exhaled breath. Transfer matrix and green methods are used to simulate the interaction between acoustic waves and the proposed sensor. The band gaps using the green method coincide with the transmittance spectra by the transfer matrix. The suggested sensor recorded a sensitivity of 5.3 H z . m - 1 . s \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$5.3 Hz.{m}<^>{-1}.s$$\end{document} , a figure of merit of 10,254 m - 1 . s \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${m}<^>{-1}.s$$\end{document} , a detection limit of 5 x 10 - 6 m . s - 1 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$5\times {10}<^>{-6} m.{s}<^>{-1}$$\end{document} , and a quality factor of 3 x 10 6 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$3\times {10}<^>{6}$$\end{document} . Furthermore, the efficiency shows that the proposed design is appropriate as a diagnostic sensor for different diseases such as chronic obstructive pulmonary. Besides, cylindrical-adapted sensors are urgently needed in medicine, industry, and biology because they can simultaneously be used for fluid transport and detection.
Keywords:
Acoustic waves
Gas sensor
Parallel resonators
Phononic crystal
Carbon dioxide concentration
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Scientific Reports cover
Scientific Reports
IF:
3.9
Papers:
27.8W
Citations:
83.5W

Organization

B
Beni Suef University
Scholars:
3.4K
Papers: 2.7K
Citations: 54
U
Ural Federal University
Scholars:
4.4K
Papers: 3.7K
Citations: 5.0K
E
egyptian knowledge bank (ekb)
Scholars:
11.6W
Papers: 9.3W
Citations: 84
K
King Khalid University
Scholars:
1.1W
Papers: 1.3W
Citations: 1.5W
researcher View more organizations